Table 6. Absolute Amplitude Accuracy (Continued)
Center Frequency
Absolute Amplitude Accuracy,
Temperature 23 °C ± 5 °C (dB)
>3 GHz to 3.9 GHz
1.3
>3.9 GHz to 4.4 GHz
1.5
Note
Absolute amplitude accuracy uses a correction coefficient in EEPROM to
improve performance. Performance is verified over the first 45 dB of RX
attenuation.
Note
Correction coefficients in EEPROM are valid only when the baseband
amplifier is in the signal path.
Noise Density
Table 7. Noise Density
Center Frequency
Average Noise Level (dBm/Hz),
Temperature 23 °C ± 5 °C
>200 MHz to 1 GHz
-163
>1 GHz to 2 GHz
-163
>2 GHz to 3 GHz
-162
>3 GHz to 3.5 GHz
-160
>3.5 GHz to 3.9 GHz
-158
>3.9 GHz to 4.4 GHz
-148
Note
Performance is measured with an input reference level of -48 dBm and
with 0 dB of RX attenuation.
NI 5791R User Manual and Specifications | © National Instruments | 23