background image

24

Installation Manual for Comfort Pack

 

Electric Units

 

1.

 National Comfort Products warrants to its customers that its product shall be free from defects in material and workmanship 

under normal use and regular service and maintenance as follows:
 

HEAT EXCHANGERS 

(Gas units only): for ten years from the date of original installation.   

  

ALL OTHER PARTS:  

For all other parts except the Heat Exchanger, for five years from the date of original installation.   

 

Customer must register the product within 60 days of purchase. If Customer cannot adequately document date of installation, 

then, for purposes of determining the warranty period, the date of installation shall be 60 days from the date of purchase.  

 

2.

   This warranty does not extend to any damages or losses due to misuse, accident, abuse, neglect, normal wear and tear, 

negligence (other than National Comfort’s), unauthorized modification or alteration; use beyond rated capacity; unsuitable power 

sources or environmental conditions; improper installation, repair, handling, maintenance or application; damage as a result of fire, 

wind, floods, lightning, or corrosive conditions; or any other cause not the fault of National Comfort.  By way of example and without 

limitation, the following do not constitute a defect in workmanship and materials and are not covered by this warranty: slugging of 

liquid refrigerant or oil, unstable line voltage, lightning, operating without proper lubrication, and operating without factory provided 

safeties.  Any installation that impairs or impedes air flow negatively impacts performance and causes premature equipment failure 

that voids this warranty.  For example, installation behind a brick façade or the addition of a brick pattern façade, i.e. pigeon holes 

impedes air flow and shall void this warranty. No warranty will apply if the input section exceeds the rated input as indicated on the 

nameplate by more than 5%, or if the heat section in the judgement of the manufacture has been subject to misuse, negligence, 

accident, corrosive atmospheres, atmospheres contacting any contaminant (silicone, aluminum oxide, etc.), excessive thermal 

shock, physical damage, impact, abrasion, unauthorized alterations, or operation contrary to the manufacture’s printed instructions, 

or if the serial number has been altered, defaced, or removed.

 

3.

   

SOLE WARRANTY 

 

 

The warranties identified herein constitute National Comfort’s sole and exclusive warranties with respect to the goods and 

are in lieu of and exclude all other warranties, express or implied, arising by operation of law or otherwise, including without limitation, 

merchantability and fitness for a particular purpose whether or not the purpose or use has been disclosed to National Comfort in 

specifications, drawings or otherwise, and whether or not National Comfort’s goods are specifically designed and/or manufactured 

by National Comfort for Customer’s use or purpose.

 

4.

   

LIMITATION OF REMEDY

 

The sole and exclusive remedy for breach of any warranty hereunder (other than the warranty provided herein) shall be 

limited to repair, replacement, credit or refund of the purchase price to distribution as set forth herein.  

 

National Comfort is not responsible for any other item including but not limited to local transportation, freight, removal of 

any compressor or part, any labor associated therewith, service or diagnosis calls, refrigerant, or costs for returning any defective 

compressor or part.   

 

5.

  

LIMITATION OF WARRANTY

 

NATIONAL COMFORT MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED, ORAL OR WRITTEN, RELATED 

TO THE GOODS, INCLUDING ANY WARRANTY OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE, 

WHICH ARE EXPRESSLY DISCLAIMED.  NATIONAL COMFORT SHALL NOT BE LIABLE FOR SPECIAL, INCIDENTAL, OR 

CONSEQUENTIAL DAMAGES OR LOSSES FROM ANY CAUSE WHATSOEVER, INCLUDING, WITHOUT LIMITATION, LOSS 

OF USE, COMMERCIAL PROFITS, OR CUSTOMER GOODWILL, AND ANY OTHER CLAIMS BASED ON CONTRACT OR TORT, 

WHETHER OR NOT ARISING FROM NATIONAL COMFORT’S NEGLIGENCE.   

 

National Comfort shall not be liable for damages caused by delay in performance and the remedies of Customer set forth 

in this agreement are exclusive. In no event, regardless of the form of the claim or cause of action (whether based in contract, 

infringement, negligence, strict liability, other tort or otherwise) shall National Comfort’s liability to Customer and/or its customers 

exceed the price paid by Customer for the specific goods or portion of the goods provided by National Comfort giving rise to the claim 

or cause of action, and Customer shall indemnify and hold harmless National Comfort for any damages incurred by National Comfort 

in excess thereof. Customer agrees that in no event shall National Comfort’s liability to Customer and/or its customers extend to 

include incidental, consequential, or punitive damages.

Continued on next page

HEATING & A/C EQUIPMENT

NATIONAL

COMFORT

PRODUCTS

®

 COMFORT PACK 

LIMITED WARRANTY

539 Dunksferry Road 

|

 Bensalem, PA 19020 

|

 215-244-1400 

1-800-523-7138 

Fax: 215-639-1674

A Division of National Refrigeration & Air Conditioning Products, Inc.

Summary of Contents for CPE Series

Page 1: ...This manual must be left with the homeowner for future reference National Comfort Products A Division of National Refrigeration and Air Conditioning Products Inc 539 Dunksferry Road Bensalem PA 19020...

Page 2: ......

Page 3: ...e 11 Maintenance page 12 Dimensional Drawing page 13 Electric Data Performance Data page 14 Comfort Pack Electric CFM Temperature Rise page 15 Air Flow page 15 U 0 Wiring Schematic 0 kw page 18 U 3 Wi...

Page 4: ...Universal Chassis Edition Generation Nominal Cooling Capacity 11 12 000Btu 17 18 000Btu 23 24 000Btu A No Grille B Slotted Filter Door C No Grille with Slotted Filter Door Heating Capacity Electric 0...

Page 5: ...CE PERSONNEL FOR PROPER INSTALLATION ADJUSTMENT AND OPERATION OFTHISUNIT READTHESEINSTRUCTIONSTHOROUGHLY BEFORE ATTEMPTING INSTALLATION OR OPERATION FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN...

Page 6: ...elay Once W1 W2 or G is energized the fan will be operated Once de energized the fan will run for an additional 5 seconds Faults If multiple inputs are received with a cooling input Y than the board w...

Page 7: ...SECONDARY DRAIN THROUGH GROMMET OF CHASSIS AND CONNECT TO FLEXIBLE TUBING PRIME TRAP PRIOR TO OPERATING INSTALL THE LOWER ACCESS PANEL ON THE CABINET TURN ON POWER TO THE UNIT ALL phases of this insta...

Page 8: ...ure proper drainage and allow chassis removal The drain line should pitch downward at least 1 per 10 ft to an open building drain trap SECONDARY DRAIN TRAP MUST BE INSTALLED Drain Pan 3 4 I D Flexible...

Page 9: ...iods of rain and wind the primary drainage path may not be adequate to handle the load Secondary precautions may also be required but not limited to the following Seal flashing to unit Floor drain Add...

Page 10: ...C22 1 In addition the installer should be aware of any local ordinances or utility company requirements that might apply Check the rating plate for the supply voltage and current requirements A dedica...

Page 11: ...nd that the service provided by the utility is sufficient to handle the additional load imposed by this equipment Power wiring must comply with national state and local codes Follow instructions on un...

Page 12: ...and do not require routine service The refrigeration system is sealed and factory charged with R 410A so that routine maintenance is not required The electrical controls do not require routine service...

Page 13: ...ion Manual for Comfort Pack Electric Units Comfort Pack Dimension Drawing Option B Slotted Filter Door for Open Returns 43 26 57 64 7 15 16 31 13 32 7 21 32 1 1 64 28 15 13 16 Side view 3 3 4 7 43 64...

Page 14: ...30 CPE41107 U 208 230 60 1 4 7 29 5 1 4 2 4 1 3 3 0 38 8 35 3 40 40 CPE41110 U 208 230 60 1 4 7 29 5 1 4 2 4 1 3 3 0 53 8 48 9 55 50 CPE41700 U 208 230 60 1 6 5 37 5 1 4 1 8 3 6 1 3 3 0 13 13 15 15 CP...

Page 15: ...80 29 2 520 32 6 450 37 7 380 44 6 Black 4 550 30 8 500 33 9 430 39 4 340 49 9 240 70 6 Orange 5 415 40 9 325 52 2 225 75 4 n a n a n a n a CPE41707 Red 1 780 21 7 770 22 0 760 22 3 725 23 4 680 24 9...

Page 16: ...80 35 8 520 40 0 450 46 2 380 54 7 Black 4 550 37 8 500 41 6 430 48 3 340 61 1 240 86 6 Orange 5 415 50 1 325 63 9 225 92 3 n a n a n a n a CPE41707 Red 1 780 26 6 770 27 0 760 27 3 725 28 7 680 30 6...

Page 17: ...715 690 660 620 560 Blue 3 620 580 520 450 380 Black 4 550 500 430 340 240 Orange 5 415 325 225 X X CPE417 Red 1 780 770 760 725 680 Yellow 2 715 690 660 620 560 Blue 3 620 580 520 450 380 Black 4 55...

Page 18: ...18 Installation Manual for Comfort Pack Electric Units U 00 Wiring Schematic 0Kw...

Page 19: ...19 Installation Manual for Comfort Pack Electric Units U 3 Wiring Schematic Electric Heat 3 5 7 10Kw...

Page 20: ...20 Installation Manual for Comfort Pack Electric Units U 3 Wiring Schematic Electric Heat 15Kw...

Page 21: ...12 Fuse Panel 14693031 14693030 14693029A Top Mount Angle 14256101 Control Board Wiring 14299001 14299002 Upper Intake Grille 14256438 Control Board 14262041 Lower Discharge Grille 14256437 Contactor...

Page 22: ...25397 TXV 14275100 14275117 14275118 Outdoor Fan Motor 14270057 14270044 14270057 Outdoor Coil Mount 14256430 14256434 Drier 14275947 Outdoor Fan 14214042 Outdoor Motor Mount 14270101 Indoor Blower Mo...

Page 23: ...Reading between Terminals C R __________ 5 Compressor Winding OHM Reading between Terminals R S __________ 6 Compressor Winding OHM Reading between Terminals C Ground __________ 7 Compressor Winding O...

Page 24: ...to the goods and are in lieu of and exclude all other warranties express or implied arising by operation of law or otherwise including without limitation merchantability and fitness for a particular p...

Page 25: ...ure shall render the warranty void B Compressors In addition to the above referenced requirements Customer is also required to purchase a replacement compressor and return the original compressor to N...

Page 26: ...26 Installation Manual for Comfort Pack Electric Units Notes...

Page 27: ...27 Installation Manual for Comfort Pack Electric Units Notes...

Page 28: ...TING A C EQUIPMENT NATIONAL COMFORT PRODUCTS National Comfort Products A Division of National Refrigeration Air Conditioning Products Inc 539 Dunksferry Road Bensalem PA 19020 1 800 523 7138 Fax 215 6...

Reviews: