background image

25

Installation Manual for Comfort Pack

 

Electric Units

The term “consequential damages” shall include, but not be limited to, loss of anticipated profits, business interruption, loss 

of use, revenue, reputation and data, costs incurred, including without limitation, for capital, fuel, power and loss or damage 

to capital or equipment. Customer agrees that all instructions and warnings supplied by National Comfort will be passed on to 

those persons who use the Goods. National Comfort’s Goods are to be used in their recommended applications and all warning 

labels adhered to the Goods by National Comfort are to be left intact.

 

It is expressly understood that any technical advice furnished by National Comfort before or after delivery in regard to 

the use or application of the Goods is furnished without charge, and National Comfort assumes no obligation or liability for the 

advice given or results obtained, all advice being given and accepted at Customer’s sole risk.

 

6.   WARRANTY PROCEDURE

 

For All Warranty Claims. Customer must register the product with National Comfort within 60 days from purchase. 

Failure to timely register the product may void the warranty. Any claim for warranty shall be made within thirty days of discovery 

and in any event, within thirty days from removal of the compressor or part from the unit. Failure to make a timely claim 

shall void the warranty. Prior authorization from National Comfort is required for all warranty claims. Any claim for warranty 

must be first reported to National Comfort in writing specifying the unit, serial number, date of purchase and date of original 

installation.  Customer shall also request a Return Material Authorization (“RMA”) from National Comfort to initiate the warranty 

claim process.  Issuance of an RMA by National Comfort is not an acknowledgment that the defect is covered by this Warranty. 

Any replacement compressor or part is warranted for the original product warranty, or for one year from the date of shipment of 

the replacement compressor/part, whichever is later.  
 

A.    Heat Exchangers.

 In addition to the above-reference requirements, customer is also required to purchase a 

replacement heat exchanger and return the original heat exchanger to National Comfort at National’s discretion, freight prepaid. 

If National Comfort determines that there is a defect in material or workmanship in the heat exchanger that is covered by this 

Warranty, then National Comfort shall credit Customer for the cost of the new replacement heat exchanger. If National Comfort 

determines that the defect in material or workmanship is not covered by this Warranty, then no credit shall be issued. A copy 

of the invoice of the replacement heat exchanger and completed RMA must accompany the original heat exchanger for which 

warranty is claimed. National Comfort reserves the right to request additional documentation. The failure to follow this procedure 

shall render the warranty void. . 
 

B.    Compressors

. In addition to the above-referenced requirements, Customer is also required to purchase a 

replacement compressor and return the original compressor to National Comfort at National’s discretion. If the defect is reported 

to National Comfort within one year from the date of original installation or within 20 months from the date of manufacture of the 

compressor (as determined by the compressor serial number), whichever occurs first, then Customer may take the compressor 

to any Authorized Copeland Distributor for replacement of said compressor. If the defect is reported to National Comfort after 

one year from the date of installation or after 20 months from the date of manufacture of the compressor (as determined by the 

compressor serial number), whichever occurs first, but before the expiration of five years from the date of installation, then the 

compressor should be returned to National Comfort at National’s discretion and Customer shall purchase a new compressor. 

If National Comfort determines that there is a defect in material or workmanship that is covered by this Warranty, then National 

shall credit Customer for the cost of the new replacement compressor.  If National Comfort determines that the defect in material 

or workmanship is not covered by this Warranty, then no credit shall be issued.  A copy of the invoice of the replacement 

compressor and completed RMA must accompany the compressor.  National Comfort, at its sole discretion, may also require 

Customer to supply the compressor tag.  The failure to follow this procedure shall render the warranty void. 

  

B.    Other Parts.

 . In addition to the above-referenced requirements, Customer is required to purchase a replacement 

part for the original part for which Customer is making a warranty claim. The original part for which warranty is claimed is to be 

returned to National Comfort at National’s discretion, freight prepaid.  If National Comfort determines that there is a defect in 

material or workmanship in the part that is covered by this Warranty, then National Comfort shall credit Customer for the cost 

of the new replacement part. If National Comfort determines that the defect in material or workmanship is not covered by this 

Warranty, then no credit shall be issued. A copy of the invoice of the replacement part and completed RMA must accompany the 

original part for which warranty is claimed. National Comfort reserves the right to request additional documentation. The failure 

to follow this procedure shall render the warranty void.  

 

7.   SHIPPING INSTRUCTIONS 

 

A.  Compressors

. . Returned compressors must be totally secured by use of shipping lugs taken from the replacements 

compressors and clearly marked with the RMA number. Do not use tape, rags or putty to seal the compressor. Line connections 

should be sealed with rubber plugs.  All scroll compressors must be securely bolted, banded, and stretch wrapped to a skid in 

the upright position. 
 

B

.  

Parts.

 All other returned parts must be securely packaged and clearly marked with its corresponding RMA number 

provided from NCP.   

Summary of Contents for CPE Series

Page 1: ...This manual must be left with the homeowner for future reference National Comfort Products A Division of National Refrigeration and Air Conditioning Products Inc 539 Dunksferry Road Bensalem PA 19020...

Page 2: ......

Page 3: ...e 11 Maintenance page 12 Dimensional Drawing page 13 Electric Data Performance Data page 14 Comfort Pack Electric CFM Temperature Rise page 15 Air Flow page 15 U 0 Wiring Schematic 0 kw page 18 U 3 Wi...

Page 4: ...Universal Chassis Edition Generation Nominal Cooling Capacity 11 12 000Btu 17 18 000Btu 23 24 000Btu A No Grille B Slotted Filter Door C No Grille with Slotted Filter Door Heating Capacity Electric 0...

Page 5: ...CE PERSONNEL FOR PROPER INSTALLATION ADJUSTMENT AND OPERATION OFTHISUNIT READTHESEINSTRUCTIONSTHOROUGHLY BEFORE ATTEMPTING INSTALLATION OR OPERATION FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN...

Page 6: ...elay Once W1 W2 or G is energized the fan will be operated Once de energized the fan will run for an additional 5 seconds Faults If multiple inputs are received with a cooling input Y than the board w...

Page 7: ...SECONDARY DRAIN THROUGH GROMMET OF CHASSIS AND CONNECT TO FLEXIBLE TUBING PRIME TRAP PRIOR TO OPERATING INSTALL THE LOWER ACCESS PANEL ON THE CABINET TURN ON POWER TO THE UNIT ALL phases of this insta...

Page 8: ...ure proper drainage and allow chassis removal The drain line should pitch downward at least 1 per 10 ft to an open building drain trap SECONDARY DRAIN TRAP MUST BE INSTALLED Drain Pan 3 4 I D Flexible...

Page 9: ...iods of rain and wind the primary drainage path may not be adequate to handle the load Secondary precautions may also be required but not limited to the following Seal flashing to unit Floor drain Add...

Page 10: ...C22 1 In addition the installer should be aware of any local ordinances or utility company requirements that might apply Check the rating plate for the supply voltage and current requirements A dedica...

Page 11: ...nd that the service provided by the utility is sufficient to handle the additional load imposed by this equipment Power wiring must comply with national state and local codes Follow instructions on un...

Page 12: ...and do not require routine service The refrigeration system is sealed and factory charged with R 410A so that routine maintenance is not required The electrical controls do not require routine service...

Page 13: ...ion Manual for Comfort Pack Electric Units Comfort Pack Dimension Drawing Option B Slotted Filter Door for Open Returns 43 26 57 64 7 15 16 31 13 32 7 21 32 1 1 64 28 15 13 16 Side view 3 3 4 7 43 64...

Page 14: ...30 CPE41107 U 208 230 60 1 4 7 29 5 1 4 2 4 1 3 3 0 38 8 35 3 40 40 CPE41110 U 208 230 60 1 4 7 29 5 1 4 2 4 1 3 3 0 53 8 48 9 55 50 CPE41700 U 208 230 60 1 6 5 37 5 1 4 1 8 3 6 1 3 3 0 13 13 15 15 CP...

Page 15: ...80 29 2 520 32 6 450 37 7 380 44 6 Black 4 550 30 8 500 33 9 430 39 4 340 49 9 240 70 6 Orange 5 415 40 9 325 52 2 225 75 4 n a n a n a n a CPE41707 Red 1 780 21 7 770 22 0 760 22 3 725 23 4 680 24 9...

Page 16: ...80 35 8 520 40 0 450 46 2 380 54 7 Black 4 550 37 8 500 41 6 430 48 3 340 61 1 240 86 6 Orange 5 415 50 1 325 63 9 225 92 3 n a n a n a n a CPE41707 Red 1 780 26 6 770 27 0 760 27 3 725 28 7 680 30 6...

Page 17: ...715 690 660 620 560 Blue 3 620 580 520 450 380 Black 4 550 500 430 340 240 Orange 5 415 325 225 X X CPE417 Red 1 780 770 760 725 680 Yellow 2 715 690 660 620 560 Blue 3 620 580 520 450 380 Black 4 55...

Page 18: ...18 Installation Manual for Comfort Pack Electric Units U 00 Wiring Schematic 0Kw...

Page 19: ...19 Installation Manual for Comfort Pack Electric Units U 3 Wiring Schematic Electric Heat 3 5 7 10Kw...

Page 20: ...20 Installation Manual for Comfort Pack Electric Units U 3 Wiring Schematic Electric Heat 15Kw...

Page 21: ...12 Fuse Panel 14693031 14693030 14693029A Top Mount Angle 14256101 Control Board Wiring 14299001 14299002 Upper Intake Grille 14256438 Control Board 14262041 Lower Discharge Grille 14256437 Contactor...

Page 22: ...25397 TXV 14275100 14275117 14275118 Outdoor Fan Motor 14270057 14270044 14270057 Outdoor Coil Mount 14256430 14256434 Drier 14275947 Outdoor Fan 14214042 Outdoor Motor Mount 14270101 Indoor Blower Mo...

Page 23: ...Reading between Terminals C R __________ 5 Compressor Winding OHM Reading between Terminals R S __________ 6 Compressor Winding OHM Reading between Terminals C Ground __________ 7 Compressor Winding O...

Page 24: ...to the goods and are in lieu of and exclude all other warranties express or implied arising by operation of law or otherwise including without limitation merchantability and fitness for a particular p...

Page 25: ...ure shall render the warranty void B Compressors In addition to the above referenced requirements Customer is also required to purchase a replacement compressor and return the original compressor to N...

Page 26: ...26 Installation Manual for Comfort Pack Electric Units Notes...

Page 27: ...27 Installation Manual for Comfort Pack Electric Units Notes...

Page 28: ...TING A C EQUIPMENT NATIONAL COMFORT PRODUCTS National Comfort Products A Division of National Refrigeration Air Conditioning Products Inc 539 Dunksferry Road Bensalem PA 19020 1 800 523 7138 Fax 215 6...

Reviews: