PACIFIC M35
14 |
P a g e
PACIFIC M35 REV.01-17 COD. PA201-M35-ENG
Nardi Compressori – www.nardicompressori.com
outgoing air (m / sec) and the section of the exhaust duct where the measurement is made (m²) and then calculate it
using the formula in Table E.
Air circulation ( m³/h ) = Cross Sectional Area of the Duct ( m² ) x Air Speed ( m/sec ) x 3600
Tab. E
To calculate the dimensions of the intake duct, it is recommended that the speed of the incoming air is not less than 5 m
/ sec and should not be more than 10 m / sec. We suggest using the formula in Table F to calculate the cross sectional
area of the duct with an air speed of 5 m / sec.
Cross Sectional Area of the Duct ( m² ) = Minimum air circulation ( m³/h ) / 5 (Air Speed m/sec) x 3600
Tab. F
4.05 INTAKE PIPE :
If you decide to place the intake of the compressor in a different location of that of the compressor itself, you can
connect a pipe to the intake of the compressor. It is important that this pipe has a diameter of 40 mm or more. Make sure
it is not plugged or bent so as to create a bottleneck. At its end it is recommended to put a filter.
Once connected check the time to refill cylinders to make sure that the compressor has not decreased the air delivery.
If this situation is present, check the pipe because the compressor may be going into depression and the causes can be:
Pipe chokes
Pipe is too long (In this case the cross sectional area of the pipe should be increased).
4.06 ELECTRIC LINE CONNECTION:
For the electrical installation you must follow these steps:
In this manual you will find a diagram of the electrical control panel of the compressor that indicates how to
connect the compressor to the mains.
Have an electrician check that the system is compliant and that it can support the maximum power draw of the
compressor shown under the CE label by NARDI COMPRESSORI.
We recommend installing a circuit breaker or fuse adapted to the power consumption of the motor.
Check that the current reaches the voltage required by the compressor and that the plug that is used
is not undersized.
CAUTION
: When connecting the plug make sure that the fan of the compressor spins in the exact
direction of the arrow on the fan wheel cover. To reverse the rotation, just reverse two of the three
phases of the plug. Your compressor may have phase sequence problems (wrong sequence on
phase connection), in this case it will not turn on until the threads of the phase are inverted as
indicated above.
Ensure that the ground wire is connected correctly to the plug and to the electrical system.
If you change the mains cable make sure it is of the right size.
.