PACIFIC M35
26 |
P a g e
PACIFIC M35 REV.01-17 COD. PA201-M35-ENG
Nardi Compressori – www.nardicompressori.com
The minimum radius of curvature must not be less than 400mm.
Do not work on the compressor if it has just been turned off. Wait until the system cools down completely and check
carefully that the fittings are tightened properly when replacing the hoses.
The filling valve which is used to fill cylinders with compressed breathing air allows
opening and closing the passage of air. This way the pressure in the whole system
remains constant, including the hoses, so as to eliminate any infiltration of moisture
in the hoses, further optimizing the quality of the breathing air.
Moreover, once the filling operation is completed and you proceed to close the filling
valve, the air under pressure in the filling valve is automatically blown-off with no
need for additional valves.
When you close the filling valve, fully tighten it until all the air is released.
7.21 AUTOMATIC CONDENSATE DRAIN:
The drain of the condensate and oil of the two intermediate separators and of the residual moisture of the final carbon
filter takes place simultaneously and in an automatic manner, through a single exhaust system, which considerably
lowers the costs and greatly simplifies the operation. This allows the operators freedom to dedicate themselves to other
activities while filling cylinders.
Every 6 minutes
(this time interval is the default factory setting but it can be reset by the operators at a more suitable
time interval of their choice at any time). The solenoid valve opens the flow of air
for 2 seconds
which serves to trigger
the pistons connected to the intermediate separators and the final filter. The solenoid valve is equipped with a display
directly located on it.
The default factory settings are:
DRAIN CLOSED = 6 MINUTES (OFF)
DRAIN OPEN = 2 SECONDS (ON)
These settings can be changed through the electronic control panel.