Now the parameters are saved.
Now set user parameters.
7.24 ALARMS VISIBLE AND ACTIONS:
The panel can generate various alarms, normally when generating these are due to the passing
of set values by NARDI COMPRESSORI (limits) or to a signal sent by the various components
positioned at key points of the compressor. For each alarm, the display will show the message
that indicates the problem, the red LED will light up to "GENERAL ALARMS", will send a beep
and the compressor turns off automatically.
Because of the high precision of the control panel can generate an alarm very easy for example
to a power surge, then you should press the "RESET" button and check if the alarm persists for
a second time.
In the case where the same alarm persists, you should contact your local dealer and report the
problem.
The alarms that may be generated are the following:
SEQUENCE OR PLASE FAILURE:
It indicates the engine and connected wrong (running backwards)
OVER CURRENT MOTOR:
It indicates an abnormal electrical current draw.
UNDER CORRENT MOTOR:
It indicates that the engine does not respond (no lights).
SERVICE TIME ALERT:
It used to indicate that makes 200 or 100 hours must be done a service.
SERVICE TIME / NEED MAINTENANCE:
It indicates that you need to do maintenance.
OVER TEMPERATURE COMPRESSOR:
It indicates that the temperature of the compressor is too high.
TEMPERATURA SENSOR BROCKEN ON NOT CONNECTED:
It indicates that the temperature sensor is
damaged or not connected.
PRESSURE SENSOR BROCKEN ON NOT CONNECTED:
It indicates that the pressure sensor is
damaged or not connected.
OIL LEVEL:
This alarm indicates that the oil level is low.
7.25 SPECIAL WASTE DISPOSAL:
Disposal of the compressor or components must be done in accordance with the rules in force in the country of