W415-0711 / D / 05.09.13
20
EN
29
1
/
2
”
(749.3MM)
42” (1066.8MM)
6” (152.4MM)
MIN
6” (152.4MM)
MIN
NOTE: When constructing the enclosure allow
for fi nishing material thickness to maintain
clearances.
A minimum of 6" is required to combustibles from the
side of the appliance.
54” (1371.6MM)
42” (1066.8MM)
6”
(152.4MM)
MIN
6”
(152.4MM)
MIN
29
1
/
2
”
(749.3MM)
42” (1066.8MM)
54” (1371.6MM)
75
5
/
16
”
(1913MM)
106
1
/
2
”
(2552.7MM)
Objects placed in front of the appliance must be kept a minimum of 48" (1219.2mm) away from the front of the
appliance.
MAINTAIN THESE MINIMUM CLEARANCES TO COMBUSTIBLES:
Framed Enclosure
:
Rear
-
0"
to
stand-offs
Sides
-
6"
(152.4mm)
Ceiling (Enclosure)
- 84" (2133.6mm) from the base of the appliance
Ceiling (Room)
- 84" (2133.6mm) from the base of the appliance
Chimney
- 2" (50.8mm)
Hot Air Gravity Ductwork Insulation
- 1" (25.4mm)
5.1 CLEARANCE TO COMBUSTIBLES
5.2 MINIMUM ENCLOSURE CLEARANCES