BUILD IN APPLIANCES

FOR USE WITH LIQUIFIED PETROLEUM (LPG) OR NATURAL GAS

CAUTION – ALL OUTER SURFACES WILL GET HOT WHEN IN USE

RADIANT GAS FIRE

MODELS  (LPG)

FI20000 FI21000 FI22000 FI23000

MODELS  (NATURAL GAS)

FI20000NG  FI22000NG  FI23000NG

GAS APPLIANCES

PC

FI0110

Is

s

ue

5

CO

UN T RY

L E I S U  R E

USER AND INSTALLATION INSTRUCTIONS

SPINFLO LIMITED, Unit 19, Oakham Drive, Parkwood Industrial Estate

Rutland Road, Sheffield S3 9QX, ENGLAND.

TEL: + 44 (0) 114 273 8157     FAX: + 44 (0) 114 275 3094

FOR USE IN: -
GB, IE, FR, NL, BE, LU, ES, IT, NO, DE, DK, SE
WARNING

 

Only use this appliance in a well-ventilated area.
Read the instructions before use.

 

This appliance must be installed in accordance with the
regulations in force.

     

by 

NG

G

themanualsli

b

rar

y

.

c

o.uk

AS

S))

u

30

00

00

0N

NG

G

t

Summary of Contents for FI20000

Page 1: ...I S U R E USER AND INSTALLATION INSTRUCTIONS SPINFLO LIMITED Unit 19 Oakham Drive Parkwood Industrial Estate Rutland Road Sheffield S3 9QX ENGLAND TEL 44 0 114 273 8157 FAX 44 0 114 275 3094 FOR USE IN GB IE FR NL BE LU ES IT NO DE DK SE WARNING Only use this appliance in a well ventilated area Read the instructions before use This appliance must be installed in accordance with the regulations in ...

Page 2: ...2 ...

Page 3: ...3 ...

Page 4: ...4 ...

Page 5: ...5 ...

Page 6: ...AL GAS Size mm H x W x D H x W x D H x W x D H x W x D H x W x D H x W x D H x W x D Fire Front 574X614X75 574X614X75 574X614X131 639X621X75 639X621X75 574X758X60 574X758X60 Rear Box 509X484X141 509X484X141 509X484X141 509X484X141 509X484X141 509X484X141 509X484X141 Fire Opening 570 x 540 570 x 540 570 x 540 570 x 540 570 x 540 570 x 540 570 x 540 Total Input 3 8kW 3 8kW 3 8kW 3 8kW 3 8kW 3 8kW 3 ...

Page 7: ...tilated keep natural ventilation holes open or install a mechanical ventilation device mechanical extractor fan Prolonged intensive use of the appliance may call for additional ventilation for example opening a window or more effective ventilation for example increasing the level of mechanical ventilation where present The room containing the fire should have an air supply in accordance with local...

Page 8: ...econds then release OPERATION Light the fire follow ignition sequence above After ignition the setting of the fire is on LOW See Fig 2 Control Positions To adjust to HIGH setting rotate the knob fully anti clockwise until it comes to a stop To turn OFF rotate the knob fully clockwise until the line on the knob is adjacent to O on the control panel IMPORTANT IF FOR ANY REASON THE FLAME SHOULD GO OU...

Page 9: ...he appliance serviced at least once a year DO check periodically that the air vents and flue are clear from obstructions DO NOT allow children near the fire when in use DO NOT use abrasive cleaners or powders that will scratch the surfaces of the fire DO NOT during operation touch any parts of the fire other than the control knob LEAKS If a smell of gas becomes apparent the supply should be turned...

Page 10: ...pliance is suitable for installation into Holiday Homes only In all cases the national standards with regard to ventilation for the particular vehicle into which the appliance is to be installed must be adhered to The flue cavity MUST be ventilated either by a flue terminal with integrated vent or by a vent in the wall as detailed in Fig 5 The gas escape vent should be positioned as detailed in Fi...

Page 11: ... air vents are not inadvertently blocked or shut off FIXINGS The aperture for the appliance is 570mm high by 540mm wide and the appliance is fixed as shown in fig 3 The flue pipe must be fixed to the rear outlet of the appliance and to the flue terminal by the use of the worm drive clips provided Where installations do not allow a vertical rise of the flue pipe directly behind the appliance the fl...

Page 12: ...ion functions correctly and the pilot remains lit see page 3 Turn to high rate check function correct see page 4 Turn off check flame extinguished and knob position correct see page 5 Test For Spillage THIS TEST MUST BE CARRIED OUT BEFORE THE INSTALLATION IS PASSED OVER TO THE CUSTOMER Ensure all doors and windows to the room containing the fire are closed Ignite the fire and turn on to full rate ...

Page 13: ...ice should be sought from the supplier If an extractor fan is fitted in the same or adjacent room as the fire then the test should be carried out with the fan switched on FINAL CHECKS 1 Ensure all removable panels are securely attached 2 Clean off any marks or dust that may have occurred during installation 3 Ensure installation and user instructions are available for the owner IMPORTANT DO NOT OV...

Page 14: ...er pipe pilot pipe and thermocouple and remove from the control Disconnect spark ignition lead from spark electrode by pulling Unscrew locknut from mounting bracket and remove control 5 Burner replacement Remove front cover 1 Disconnect gas supply Unscrew the screw that attaches the pilot assembly to the burner Remove the locknut from the injector assembly Then remove the two screws which attach t...

Reviews: