W415-0711 / D / 05.09.13
29
EN
BLOWER INSTALLATION
NOTE: Consideration should be made for blower location as the closer to
the appliance the greater the air fl ow noise will be. Blower may
be installed on either side of the unit.
A.
Position the blower to an inside or outside wall into a framed
opening 12
3
/
8
” wide by 10
1
/
2
” high (314.3mm by 266.7mm).
(Outside wall not recommended in colder climates as cold air
may be drawn into the house even when the blower is off.)
The blower housing should be installed onto a level surface
large enough to support the blower assembly. Allow for fi nishing
material when securing the blower housing, as the grille mounts to
the housing.
NOTE: Blower housing may be installed in side a home that has
suffi cient air fl ow.
COLLAR INSTALLATION
B.
Determine which side of the appliance the blower is to be located
on. Remove and discard the cover plate and install the 6”
(152.4mm) collar.
Secure by reaching through the collar and bending the tabs.
Use sealant to ensure that the connection is air tight.
ELECTRICAL CONNECTION
C.
Remove the junction box covers on the appliance and the
blower.
Removing the junction box cover on the appliance exposes 4
black, labeled wires:
Two wires labelled "by-pass" - go to by-pass (summer) switch
(not supplied - overrides the thermally activated switch enabling
the user to run the blower without heat).
IMPORTANT:
If the by-pass, (summer) switch is not desired,
terminate the wires by attaching wire nuts to by-pass
(summer) switch wire leads separately (do not connect
together).
One wire labelled "blower" - connects to fan-speed control
rheostat and then the fan-speed control connects to white blower
wire.
One wire labelled "L1" - connects to power (hot lead).
-
Removing the junction box cover on the blower
exposes 3 coloured wires:
This appliance is supplied with two micro (pressure) switches
(the blower on high draws 3.0 amps using
120V (approx. 360w)
and a thermally activated switch.
Ensure that the pressure switch actuating arm protrudes through the
faceplate when installed and moves freely.
The blower will only operate when the doors are fully closed and the air control
is not set to it’s “super low” burn rate.
7.2 OPTIONAL NZ64 BLOWER INSTALLATION
ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE
WITH LOCAL CODES AND WITH THE NATIONAL ELECTRIC CODE ANSI/NF NO. 70-CURRENT (IN THE
UNITED STATES), OR WITH THE CURRENT CSC22.1 CANADIAN ELECTRIC CODE (IN CANADA).