4.0 INSTALLATION
NOTE: All venting connections must be in compliance with the chimney manufacturers installation
instructions.
This appliance was tested to CAN/ULC S610 and UL 127 Factory Built Fireplace Standards. This appliance has
met the test criteria for Zero Clearance Installation to Combustible Surfaces and Certifi ed to burn fi rewood only.
Any 7” (177.8mm) or 8” (203.2mm) diameter chimney listed to these standards may be installed. In accordance
with these standards, the appliance may also be connected to any chimney listed to CAN/ULC-S604 and CAN/
ULC-S629 for Canada or UL-103HT for the United states.
Installation of all types of factory-built chimney systems is to
be in accordance with the chimney manufacturers installation
instructions. An appropriate chimney manufacturers anchor base
plate is required in order to initiate their system. An anchor base
plate gasket is supplied that suits a 7” (177.8mm) chimney. If 8”
(203.2mm) is used then cut hole in gasket to suit. Use the high
temperature gasket, supplied, to seal between the anchor plate and
the appliance top.
Complete installation instructions for Selkirk Ultra Temp Chimney for Canada and Ultra Temp Platinum Chimney
for USA, refer to: www.selkirkinc.com/products/chimney.aspx
A chimney venting the appliance shall not vent any other appliance. The minimum overall chimney height from
the top of the appliance is 15 feet (4.6m). The maximum overall chimney height from the top of the appliance is
34 feet (10.4m).
Factory-built chimney systems for use in dwellings constructed for three or more families must be enclosed above
the room in which the appliance is located. This enclosure must have a fi re resistance rating equal to or greater
than that of the fl oor or roof assembly through which they pass.
The chimney should not be built with an offset angle in excess of 45° in Canada and 30° in USA.
Ensure that minimum clearances are maintained.
Portions of the chimney that extend through accessible spaces must always be encased to avoid personal
contact with the chimney and thereby avoid damage to the chimney.
The chimney must be supported at a maximum of 20 foot (6.1m) intervals (approx. 200 lbs/20 FT (90.7k/6.1m)).
63.1A
ANCHOR PLATE
ANCHOR PLATE GASKET
APPLIANCE TOP
ANCHOR PLATE FOR A FACTORY
BUILT CHIMNEY
NEVER INSTALL A SINGLE WALL SLIP SECTION OR SMOKE PIPE IN A CHASE STRUCTURE.
THE HIGHER TEMPERATURE OF THIS SINGLE WALL PIPE MAY RADIATE SUFFICIENT HEAT TO
COMBUSTIBLE CHASE MATERIALS TO CAUSE A FIRE.
TO AVOID DANGER OF FIRE, ALL INSTRUCTIONS MUST BE STRICTLY FOLLOWED, INCLUDING
THE PROVISION OF AIR SPACE CLEARANCE BETWEEN CHIMNEY SYSTEM AND ENCLOSURE.
TO PROTECT AGAINST THE EFFECTS OF CORROSION ON THOSE PARTS EXPOSED TO THE
WEATHER, WE RECOMMEND THAT THE CHASE TOP BE PAINTED WITH A RUST-RESISTANT PAINT.
MAINTAIN A MINIMUM 2" AIR CLEARANCE TO ALL PARTS OF THE CHIMNEY SYSTEM AT ALL TIMES.
FAILURE TO MAINTAIN THIS 2" AIR CLEARANCE WILL CAUSE A STRUCTURE FIRE.
DETAILED INSTRUCTIONS FOR INSTALLATION OF THE CHASE TOP, STORM COLLAR AND
TERMINATION CAP ARE PACKAGED WITH THESE PARTS.
FIRESTOP SPACERS MUST BE USED WHENEVER THE CHIMNEY PENETRATES A CEILING/FLOOR
AREA.
THE CHIMNEY MUST BE SOUND AND FREE OF CRACKS. CLEAN YOUR CHIMNEY A MINIMUM OF TWICE
A YEAR AND AS REQUIRED.
4.1 CHIMNEY