Freedom F-64 Programming Instructions 

L

 NAPCO Security Systems 

 

Page 52

 

WI1502A  9/06 

 

ALPHABETICAL INDEX (CONT'D) 

ZONE DESCRIPTIONS 

ENTERING, 12 

ZONE OPTIONS - ZONES 1 TO 16 (ADDRESS 0900-

1016), 30 

ZONE OPTIONS - ZONES 17 TO 32 (ADDRESS 1029-

1144), 31 

ZONE OPTIONS - ZONES 33 TO 48 (ADDRESS 1157-

1272), 32 

ZONE OPTIONS - ZONES 49 TO 64 (ADDRESS 1285-

1400), 33 

ZONE RESPONSE, 41 
 

Summary of Contents for F-64PROG

Page 1: ...to the wiring diagram and connect the Siren Aux Power PGM Output Remote Bus earth ground Zone and Telephone wiring NOTE See Installation Instructions WI1501 2 Connect AC power first and then the battery 3 Configure the Touchpad see page 40 4 Access the Easy Menu Driven Program Mode Press 456789 R Press NO Q until ACTIVATE PROGRAM Y N appears on the programmer display Press YES P to Enter Dealer Pr...

Page 2: ...TANT NOTICE F 64 panel version 30 requires the use of the following version programmer F 64PROG Version 01 Upon entering program mode the programmer display will flash the control panel firmware version followed by the programmer firmware version F 64PROG 3001 If Gemini keypads are installed in the system in addition to the required Freedom F 64TP or F 64TP H Touch pads the following version keypa...

Page 3: ...ccount Number 9 Central Station Receiver 1 Format 9 Enter User Codes 9 RF Transmitter Points 10 Keyfob Transmitters as Arm Disarm Control Devices 10 Keyfob Transmitters as Zone Input Devices 11 Enter Zone Descriptions 11 Enter Date 11 Enter Time 11 Dealer Code 11 Test Timer 11 Clear Dealer Program 11 Cold Start 11 ENTERING ZONE DESCRIPTIONS 12 DIRECT ADDRESS PROGRAM MODE 13 Direct Address Overview...

Page 4: ...on confirming a successful download Callback Method An installed unattended panel may be programmed or reprogrammed remotely using the Callback Method Download feature of the PCD Windows software Remote downloading requires a modem compatible with the PCI2000 3000 Upon answering the call from the computer the panel will verify the Download Security Code and if con firmed will establish a connectio...

Page 5: ... c press U and start over This procedure will automatically set up system keypads Touchpads EZMs wireless transmitters etc After your basic default pro gram has been loaded you may alter it as necessary in the Direct Address Program Mode ACCESSING DEALER PROGRAM MODE CUSTOMIZING A DEFAULT PROGRAM For new panels you can design a default program that will best suit your application Using this proced...

Page 6: ... 01 to 64 Directly enter each zone number including leading zeros and press U to save and then repeat for any additional zone s Press the NEXT YES button to proceed 2 Wire Fire Zones in Area 1 New Program Only Enter the zone number of any Fire Zone from previous question to be used with 2 wire smoke detectors Valid entries are 07 and 08 Directly enter each zone number including leading zeros Press...

Page 7: ...ne number including leading zeros Press U to save and then repeat for any additional zone s Press the NEXT YES button to proceed NOTE A PGM2 Timeout of 15 minutes will automatically be programmed Sensor Watch Zones New Program Only Enter the zone numbers of zones to be Sensor Watch zones Valid entries are from 01 to 64 Directly enter each zone number including leading zeros Press U to save and the...

Page 8: ...mber of the Touchpad including leading zeros Press ENTER to save Press the NEXT YES button to proceed Enter the Touchpad PIR Zone Number Enter the zone number to associate with the Touchpad PIR Valid entries are from 01 to 64 Directly enter the number of the zone including leading zeros Press ENTER to save Press the NEXT YES button to proceed Enter Door Number 1 Zone Number Enter the zone number t...

Page 9: ...ursor to the Area 1 Options Level Refer to the table below for available options For Area 2 Options press R once again For Area 3 4 Options press R a third and fourth time If Enable Global Ambush Code Address 1422 is enabled and Global Ambush Code Address 2045 is not left blank do not program the first two digits of ANY User Code the same as the Global Ambush Code See Address 2045 further in this ...

Page 10: ... open point 2 loop 7 Remove the transmitter battery then re install it The pro grammer will beep once to indicate that one point has been programmed Transmitter 287613 1 point 2 is mapped to Zone 9 KEYFOB ZONE ASSIGNMENT Keyfobs can also be assigned to zones to allow multiple wireless panic buttons on one alarm sys tem each reporting to a central station a pager or having a description in the LCD ...

Page 11: ...tion Data and Schedules Access address 2286 and press U Data entry is not allowed NOTE Some features schedules can only be programmed again with the Downloading Software DATA ENTRY AUX 1 AUX 2 OPTIONS 0 None 1 Relay Group 1 Toggle 2 Relay Group 2 Toggle 9 Keypad Panic A Keypad Aux B Instant C PGM2 Ouput Toggle D Access on PGM2 Output E Arm STAY F Interior Button Direct Entry 01 EXIT DEALER PROGRAM...

Page 12: ...r below the character to be changed Enter a new charac ter to overwrite the old or press zero to delete the character 4 To generate lowercase characters the G button must be pressed and held down while pressing the number button If the G button is released during the 2 second window the current character will change to uppercase Press U to save To advance to the next zone or to any other zone move...

Page 13: ...nd accept data in number format For example Zone Features are turned on by the pressing of the programmer buttons 1 through 8 with the activated Zone s displaying the corre sponding decimal digit replacing deactivated zones which are signified by dashes EXAMPLE BIT Format with the F 64PROG Program Zones 2 4 5 and 7 as Exit Entry Follower Zones DETERMINE THE DATA ENTRIES 1 Referring to ZONE FEATURE...

Page 14: ...ving to the right upon each key press EXAMPLE DECIMAL Format with the F 64PROG Program Abort Delay to be 15 seconds DETERMINE THE DATA ENTRIES 1 Referring to SYSTEM DELAYS TIMEOUTS in the Programming Worksheets that follow the Abort Delay is located at address 1417 PROGRAM THE DATA ENTRIES 1 Enter the panel s Dealer Security Code then press R 2 Answer NO to all questions until ACTIVATE PROGRAM Y N...

Page 15: ...ELAYS TIMEOUTS in the Programming Worksheets that follow the Chime Timeout is located at address 1418 In the Chime Timeout Options table the data entries needed to assign a time out of 2 seconds are blank and 8 ENTRY TOTAL PRESS KEYPAD DISPLAYS ENTRY TOTAL PRESS KEYPAD DISPLAYS blank 0 8 8 8 1 1 1 9 9 9 2 2 2 10 G0 0 3 3 3 11 G1 B 4 4 4 12 G2 C 5 5 5 13 G3 D 6 6 6 14 G4 E 7 7 7 15 G5 F HEXADECIMAL...

Page 16: ...the PCD Windows s error check feature be utilized to reduce the possibility of programming omissions or conflicts 3 Keep the Programming Worksheets on file for future reference General Programming Steps 1 Contact the central station to ascertain receiver format data format event codes subscriber numbers and tele phone number s 2 Select the desired features by circling with a pencil the respective ...

Page 17: ...9 DEFAULTS The defaults shown on this page and on the following pages are automatically set after exiting the Easy Menu Driven Program Mode 1 Enter delay timeout in corresponding address locations above Note All entries for address 1418 are in quarter seconds 25 seconds Therefore the default of 008 results in a 2 second timeout 2 Press U to save EXIT ADDRESS 0000 DELAY sec Default 060 ENTRY ADDRES...

Page 18: ...o save PAGER FORMAT OPTIONS ADDRESS 0546 0547 LEADING DIGITS FOR PAGER FORMAT In Pager Format reporting the message typically begins with 00 However for some pager services this will cause the Pager s Voice Mail feature to activate This option allows you to program these digits to any number desired A typical Pager report is 003 22 1234 where 3 is the Event 22 is the zone and 1234 is the Subscribe...

Page 19: ...d in address 2045 For Touchpads see Ambush glossary entry in install instructions WI1501 Enter in address location both 1st and 2nd digits valid entries are 1 9 Press ENTER to save Note Do not program in CP 01 compliant systems Default blank blank Global 1st digit 2nd digit Ambush Code ADDRESS 2045 SYSTEM RESPONSE ACTIVATED BY AREA 1 EVENT TROUBLE AREA 1 SYSTEM EVENT TROUBLE ADDR AMBUSH KEYPAD PAN...

Page 20: ...ANIC KEYPAD FIRE KEYPAD AUX KEYPAD TAMPER FAIL TO OPEN FAIL TO CLOSE Keyfob Low Batt 1 2 3 4 5 6 7 8 Pulsed Alarm Output 0880 Alarm Output 0881 PGM1 Output 0882 PGM2 Output 0884 Report Event Telco 1 0885 Report Event Telco 3 0887 Default blank blank from address 0880 0887 NOTE Keypad Aux is not to be selected for UL Installations 2063 System Options Default Option OFF 1 RESERVED OFF 2 RESERVED OFF...

Page 21: ...utput on Telco Fail only when Armed OFF 5 Disable Keypad Function Mode Download OFF 5 Line Fault Test only when Armed OFF 6 Disable Callback Download OFF 6 Enable Line Fault Test OFF 7 Chirp Output on Keyfob Arm Disarm OFF 7 Inhibit System Trouble Audible at Keypad OFF 8 Change Pulse Output to Temporal Output OFF 8 Select Alarm Output for Keyfob Chirp This feature must be programmed in Fire Alarm ...

Page 22: ...tone F Ignore location Default for CS Receiver 1 Tele phone Number depends on Easy Menu Driven Pro gram Mode ques tion CENTRAL PHONE Default blank across digits 1 20 for CS Receiver Telephone Num bers 2 and 3 ADDRESS 0460 CS Receiver 1 Format ADDRESS 0482 CS Receiver 2 Format ADDRESS 0504 CS Receiver 3 Format ADDRESS 0462 0481 RIGHT DIGITS 1 20 0462 0463 0464 0465 0466 0467 0468 0469 0470 0471 047...

Page 23: ...96 0599 RIGHT DIGITS 1 4 0596 0597 0598 0599 CS Telco 3 Sub scriber Event ID Number Area 1 ADDRESS 0648 0651 RIGHT DIGITS 1 4 0648 0649 0650 0651 CS Telco 3 Sub scriber Opening Closing ID Number Area 3 ADDRESS 0640 0643 RIGHT DIGITS 1 4 0640 0641 0642 0643 CS Telco 1 Sub scriber Event ID Number System ADDRESS 0592 0595 RIGHT DIGITS 1 4 0592 0593 0594 0595 CS Telco 2 Sub scriber Event ID Number Sys...

Page 24: ...TEM REPORTING OPTIONS ADDRESS 0785 0786 0788 Default blank blank DISABLE OPENING REPORTS LEFT DIGIT RIGHT DIGIT SUM OF DATA VALUES blank ADDRESS 0785 NOTE If neither Touch tone Dialing nor Touch tone w Rotary Backup is selected then system defaults automatically to Rotary Dialing Leave blank to select Rotary Dialing CS SYSTEM REPORTING OPTIONS 1 Select the desired option entering the option number...

Page 25: ...ptions PULSE EVENT CODE will be the first digit of the 2 digit reporting code The second digit will be the second digit of the reporting zone For example for zone 9 address 0728 if the right digit is 3 then the reporting code is 39 For example for zone 15 address 0734 if the right digit is 4 then the reporting code is 45 MODEM CODES determine the zone types reported for the following formats SIA a...

Page 26: ...Users to Report Opening and Closings ADDR U49 U50 U51 U52 U53 U54 U55 U56 ADDR U57 U58 U59 U60 U61 U62 U63 U64 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Enable Opening Report Telco 1 0806 0807 Enable Closing Report Telco 1 0815 0816 Enable Opening Report Telco 3 0824 0825 Enable Closing Report Telco 3 0833 0834 USERS 65 68 Enable Users to Report Opening and Closings ADDR U65 U66 U67 U68 1 2 3 4 5 6 7 8 Enab...

Page 27: ... ADDRESS 1456 EZM Group 3 ADDRESS 1457 EZM Group 4 ADDRESS 1458 EZM Group 5 ADDRESS 1459 EZM Group 6 ADDRESS 1460 EZM TYPE DATA ENTRIES OPTION blank Not used No EZM present 1 4 Zone EZM EZM Group 7 ADDRESS 1461 EZM Group 8 ADDRESS 1462 EZM Group 9 ADDRESS 1463 EZM Group 10 ADDRESS 1464 EZM Group 11 ADDRESS 1465 EZM Group 12 ADDRESS 1466 EZM Group 13 ADDRESS 1467 EZM Group 14 ADDRESS 1468 EZM GROUP...

Page 28: ...t Option Disarming Area 1 ON 1 Area 1 Pulsed Burg Output Silenced OFF 2 Area 2 Pulsed Burg Output Silenced OFF 3 Area 3 Pulsed Burg Output Silenced OFF 4 Area 4 Pulsed Burg Output Silenced 1478 Pulsed Burg Output Turns Off upon Disarm Default Option Disarming Area 2 ON 1 Area 1 Pulsed Burg Output Silenced OFF 2 Area 2 Pulsed Burg Output Silenced OFF 3 Area 3 Pulsed Burg Output Silenced OFF 4 Area ...

Page 29: ...64PROG programmer enter corresponding option number in address location NOTE Dark shaded data value box shows option not available Press U to save MAPPING F 64TP DOORS AND PIR S ADDRESS 2090 2101 Keypad address programming locations for mapping F 64TP Doors and PIR s to the F 64 control panel are dis played in the table at right In addition in order for the F 64TP to function correctly on the F 64...

Page 30: ...re 3 0932 0996 No EOL Resistor 0933 0997 Trouble on Open 0934 0998 Trouble on Short 0935 0999 Zone Area 1 0936 1000 Zone Area 2 0937 1001 Zone Area 3 0938 1002 Keypad Sounder on Alarm 0941 1005 2 Wire Smoke Detectors B 0942 1006 Fire C 0943 1007 Fire Alarm Verification C 0944 1008 RESERVED 0945 1009 Zone ANDing Group 1 0946 1010 Zone ANDing Group 2 0947 1011 Zone ANDing Group 3 0948 1012 Zone ANDi...

Page 31: ...Easy Menu Driven Program Mode is used these features are enabled by default Enabled when Enable SIA CP 01 Features is activated Answer Yes in the EZ Programming Menu Disabled when Enable SIA CP 01 Features is activated Answer Yes in the EZ Programming Menu Disable Auto Reset on non fire zones for SIA CP 01 installations Zone Area 3 1066 1130 Zone Area 4 1067 1131 RESERVED 1081 1145 Perimeter Group...

Page 32: ...Telco 3 1187 1251 Trouble Restore 3 1188 1252 No EOL Resistor 1189 1253 Trouble on Open 1190 1254 Trouble on Short 1191 1255 Zone Area 1 1192 1256 Zone Area 2 1193 1257 Interior Stay Bypass 1196 1260 Keypad Sounder on Alarm 1197 1261 2 Wire Smoke Detectors B 1198 1262 Fire C 1199 1263 Fire Alarm Verification C 1200 1264 RESERVED 1201 1265 Zone ANDing Group 1 1202 1266 Zone ANDing Group 2 1203 1267...

Page 33: ...riven Program Mode is used these features are enabled by default Enabled when Enable SIA CP 01 Features is activated Answer Yes in the EZ Programming Menu Disabled when Enable SIA CP 01 Features is activated Answer Yes in the EZ Programming Menu Disable Auto Reset on non fire zones for SIA CP 01 installations Zone Area 3 1322 1386 Zone Area 4 1323 1387 RESERVED 1337 1401 Perimeter Group Bypass 133...

Page 34: ...5 1559 1560 1561 1562 1563 RELAY AREA TIMEOUT EVENT ID COND ADDRESS 1554 1558 RELAY EVENT 14 1554 1555 1556 1557 1558 RELAY AREA TIMEOUT EVENT ID COND ADDRESS 1574 1578 RELAY EVENT 18 1574 1575 1576 1577 1578 RELAY AREA TIMEOUT EVENT ID COND ADDRESS 1569 1573 RELAY EVENT 17 1569 1570 1571 1572 1573 RELAY AREA TIMEOUT EVENT ID COND ADDRESS 1579 1583 RELAY EVENT 19 1579 1580 1581 1582 1583 RELAY ARE...

Page 35: ...out Type from Table 5A on next page enter in corresponding left address location 5B Select Activation Conditions from Table 5B on next page enter in corresponding right address location STEP 2 AREA OPTIONS Each relay event can be assigned to Area 1 2 3 and or 4 Select the area from Table 2 on next page enter in corresponding address location STEP 1 RELAY OPTIONS The F 64 supports 16 external relay...

Page 36: ...Area 4 Arming AWAY D blank Keypad Fail D 1 EZM Fail D 2 Quickloader Device Control D 5 General System Alarm D 8 Area 1 General System Alarm D 9 Area 2 General System Alarm D 0 Area 3 General System Alarm D B Area 4 General System Alarm F blank Relay Control Group 1 F 1 Relay Control Group 2 F 8 Entry Relay Area 1 F 9 Entry Relay Area 2 F 0 Entry Relay Area 3 F B Entry Relay Area 4 7 E Area 3 Fail ...

Page 37: ... in corresponding address locations below right nibble 3 Press U to save NOTE These timers apply only to Supervised RF Transmitters see RF Transmitters in Easy Menu Driven Program Mode DATA ENTRIES blank None 1 1 2 2 RF RECEIVER S Default for Number of Receivers depends on Easy Menu Driven Program Mode question for RF Transmitters ADDRESS 2056 LEFT DIGIT Number of RF Receivers RIGHT DIGIT blank De...

Page 38: ...s 2285 then press U Data entry is not allowed NOTE Enter Easy Menu Driven Program Mode to program system again Cold Start Erases Entire Program This erases the entire program including Dealer Pro gram by erasing Program Data Zone Description Data and System Status Data similar to a new panel Access address 2286 then press U Data entry is not allowed NOTE Some features schedules can only be program...

Page 39: ...T PRESS C AT ANY TIME For the F 64PROG Programmer Scroll Down Scroll Up Exit Yes No Dealer Program Mode comprises two operational states EASY MENU DRIVEN PROGRAM MODE Used with new out of the box panels or Cold Started panels see address 2286 this mode allows the dealer to customize the factory panel program to best suit the installation The Easy Menu Driven Pro gram Mode is a menu driven utility ...

Page 40: ...cated in the center of the F 64 control panel board from pins 1 2 top two NORMAL to pins 2 3 bottom two KEYPAD CONFIGURE NOTE See wiring diagram at the end of this manual and the jumper configuration diagram at right 2 Press the STAY BYPASS and YES buttons simultaneously After a short delay the display will read OUT OF SYSTEM XX where XX indicates the keypad address 3 Press MENU for 2 seconds on t...

Page 41: ...GEM EZM series mod ules or other Touchpad EZMs it must be assigned a unique address or Group number similar to its Touchpad address If no other EZMs are to be used designate the Touchpad as Group 01 at the EZM ADDRESS 00 display In multiple EZM systems enter an assigned group num ber 01 through 14 Each EZM must have a unique assigned Group number starting with 01 and proceeding consecutively Defau...

Page 42: ...ID Be sure to install the shunt on the Secondary transmitter address jumper to ensure the transmitter is identified as the Secondary transmitter and not the Primary transmitter Install a Secondary transmitter to protect a second door that will be used only for entry or to disarm when armed Stay If YES is pressed will display PRESS RELEASE TAMPER SWITCH If learned successfully displays SEC ONDARY T...

Page 43: ...t HIGH OFF voice prompt volume ACTIVATE SIREN TEST Y N Press YES to activate burg relay output for 2 seconds DISPLAY FIRE ALARM Y N Displays list of shorted fire zones only when a fire alarm is tripped DISPLAY FIRE TROUBLE Y N Displays list of opened fire zones only when a fire trouble open on a fire zone is detected ACTIVATE FAULT FIND Y N Activates Fault Find mode The Master I FOB MUST be insert...

Page 44: ...ntral Station Receiver 1 Account Number Central Station Receiver 1 Format blank Ademco Slow Silent Knight Slow 2 Radionics Fast 3 Silent Knight Fast 4 Radionics DCI Franklin Slow 5 Universal High Speed B SIA C Ademco Point ID E Pager User Codes USER CODE up to 6 digits AREA 1 OPTIONS AREA 2 OPTIONS AREA 3 OPTIONS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 AREA 4 OPTIONS USER CODE up to 6 digits AREA 1...

Page 45: ...inted on xmtr box XMTR ZONE CHECK SUM POINT 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 RF ID printed on xmtr box Keyfob Transmitters KEYFOB Area CHECK SUM OPTION 1 OPTION 2 1 2 3 4 5 6 7 8 RF ID printed on xmtr box XMTR ZONE CHECK SUM POINT 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 RF ID printed on xmtr box XMTR ZONE CHECK SUM POINT 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 RF ID ...

Page 46: ...13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 CHARACTERS AVAILABLE See below Dealer Code Characters Available for Zone Descriptions _ 1 2 3 4 5 6 7 8 9 0 a b c e d f g h i j k l m n o p q r s t u v w x y z A B C D E F G H I J K L M N O P Q R S T U V W X Y For Zones 33 64 see next page ...

Page 47: ... 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 CHARACTERS AVAILABLE See below Dealer Code Characters Available for Zone Descriptions _ 1 2 3 4 5 6 7 8 9 0 a b c e d f g h i j k l m n o p q r s t u v w x y z A B C D E F G H I J K L M N O P Q R S T U V W X Y For Zones 1 32 see previous page ...

Page 48: ...ALARM ZONES 7 BACKLIGHT BRIGHTNESS 40 BACKLIGHT FOLLOW PIR 40 BINARY BIT FORMAT EXAMPLE 13 BYPASS ENABLE 10 BYPASS OPEN ZONES 43 CALLBACK METHOD 4 CALLBACK TELEPHONE NUMBER 18 CENTRAL STATION RECEIVER 1 ACCOUNT NUMBER 9 CENTRAL STATION RECEIVER 1 FORMAT 9 CENTRAL STATION RECEIVER 1 TELEPHONE NUMBER 9 CHANGE DATE 43 CHANGE KEYPAD BEEP VOLUME 43 CHANGE PULSE OUTPUT TO TEMPORAL OUTPUT ADDRESS 1422 21...

Page 49: ...E FAULT SCROLLING ADDRESS 1420 21 DISPLAY ALARM LOG 43 DISPLAY FIRE ALARM 43 DISPLAY FIRE LOG 43 DISPLAY FIRE TROUBLE 43 DISPLAY RF NOISE 42 DISPLAY RF SS 42 DISPLAY SYSTEM LOG 43 DISPLAY TOTAL LOG 43 DISPLAY ZN BYPASSED 43 DISPLAY ZN DIRECTORY 43 DON T CLEAR PGM2 OUTPUT WITH DISARM ADDRESS 1424 21 DOWNLOAD CALLBACK OPTIONS ADDRESS 2059 0526 0545 18 DOWNLOADING FROM A COMPUTER 4 EASY ARMING 26 EAS...

Page 50: ...Y CONTROL ADDRESS 1489 1648 34 EZM ADDRESS 41 EZM GROUP OPTIONS ADDRESS 1455 1468 27 F 64 AND GEM P1664 PANEL DIFFERENCES 2 FIRE ZONES IN AREA 1 6 FIRMWARE VERSION 2 FREEDOM F 64 WIRING DIAGRAM 60 FUNCTION MODE 4 GEM P1664 AND F 64 PANEL DIFFERENCES 2 GLOBAL AMBUSH CODE 19 GLOBAL SYSTEM EVENT TROUBLE 19 HEXADECIMAL FORMAT EXAMPLE 15 INCL SEL GRP BYPASS IN COND CLOSE STATUS ADDRESS 1420 21 INHIBIT ...

Page 51: ...S 37 RF SUPERVISORY TIMERS 37 RF TRANSMITTER POINTS 10 RPT EXIT ERR RECENT CLOSE ADDRESS 2053 21 SECURITY BYPASS 10 SELECT ALARM OUTPUT FOR KEYFOB CHIRP ADDRESS 1423 21 SENSOR WATCH ADDRESS 2050 17 SENSOR WATCH ZONES 7 SOUND ALARM ON EXIT ERROR ADDRESS 2053 21 STATUS REPORT ADDRESS 1420 21 SUPPRESS BYPASS REMINDER WHEN ARMED ADDRESS 1421 21 SYSTEM DELAYS TIMEOUTS ADDRESS 0000 0002 1413 1417 2050 2...

Page 52: ...02A 9 06 ALPHABETICAL INDEX CONT D ZONE DESCRIPTIONS ENTERING 12 ZONE OPTIONS ZONES 1 TO 16 ADDRESS 0900 1016 30 ZONE OPTIONS ZONES 17 TO 32 ADDRESS 1029 1144 31 ZONE OPTIONS ZONES 33 TO 48 ADDRESS 1157 1272 32 ZONE OPTIONS ZONES 49 TO 64 ADDRESS 1285 1400 33 ZONE RESPONSE 41 ...

Page 53: ... REPORTING OPTIONS ADDRESS 0788 24 CS RECEIVER OPTIONS ADDRESS 0460 0525 22 CS SUBSCRIBER ID OPTIONS ADDRESS 0560 0667 23 CS SYSTEM REPORTING OPTIONS ADDRESS 0670 0705 24 CS USER REPORTING OPTIONS ADDRESS 0800 0835 26 CS ZONE REPORTING OPTIONS ADDRESS 0720 0783 25 DIGITAL DIALER RPT ENTER EXIT TEST MODE ADDRESS 2053 21 DISABLE ON OFF AS EASY EXIT ADDRESS 2051 21 DISABLE 2ND CALL ANS MACHINE OVERRI...

Page 54: ...S ADDRESS 1455 1468 27 INCL SEL GRP BYPASS IN COND CLOSE STATUS ADDRESS 1420 21 INHIBIT SYSTEM TROUBLE AUDIBLE AT KEYPAD ADDRESS 1423 21 INTERIOR NORMALLY BYPASSED ADDRESS 1422 21 KEYPAD TOUCHPAD OPTIONS ADDRESS 1425 1431 29 KEYPAD TOUCHPAD OPTIONS ADDRESS 1440 1446 29 LINE FAULT TEST ONLY WHEN ARMED ADDRESS 1423 21 LUG E15 AREA 1 ARMED AWAY ONLY ADDRESS 2052 21 MAINTAINED KEYSWITCH ARMING ADDRESS...

Page 55: ...DELAYS TIMEOUTS ADDRESS 1418 1419 17 SYSTEM OPTIONS ADDRESS 0836 0871 19 SYSTEM OPTIONS ADDRESS 2045 19 SYSTEM OPTIONS ADDRESS 0872 0887 20 SYSTEM OPTIONS ADDRESS 1420 1424 21 SYSTEM OPTIONS ADDRESS 2051 2054 21 SYSTEM OPTIONS ADDRESS 2063 20 SYSTEM OUTPUT TIMEOUTS ADDRESS 1412 18 SYSTEM OUTPUT TIMEOUTS ADDRESS 1414 1416 18 VERI PHONE AUDIO PRIORITY OVER ALARMS ADDRESS 1424 21 VERI PHONE ZONES TRI...

Page 56: ...Freedom F 64 Programming Instructions L NAPCO Security Systems Page 56 WI1502A 9 06 FREEDOM F 64 WIRING DIAGRAM FREEDOM F 64 Wiring Diagram ...