L
NAPCO Security Systems
Freedom F-64 Programming Instructions
Page 11
WI1502A 9/06
Keyfob Transmitters as Zone Input Devices
(Refer to display above: press the PRIOR button to go backwards).
Each of the 4 keyfob buttons can be assigned to a zone. For example, On button = point 1; Off button =
point 2; A1 = point 3; A2 = point 4. Up to 64 keyfobs (using 1 button) or 32 keyfobs (using 2 buttons) or
16 keyfobs (using all 4 buttons) or any combination up to a maximum of 64 controlled zones can be as-
signed, providing multiple wireless panic buttons on a system, each reporting to a Central Station or a
pager and/or annunciating on a keypad/Touchpad the keyfob zone number with a description.
To assign
a keyfob to a zone:
program the keyfob as you would a transmitter, entering the keyfob's ID code, check
sum and point number at the appropriate zone. The “Quick Method” is not allowed. The zone may be
hardwired to an electrical sensor as well as assigned to a keyfob (either one will activate the zone alarm
output).
NOTE:
If assigning a keyfob to a zone, the “ON/OFF” buttons on the keyfob will no longer arm/
disarm the system. The keyfob is converted to a “panic only” device.
(Direct Entry)
Enter Date
( / / )
(Direct Entry)
Enter Time
( : )
D e a l e r C o d e
4 5 6 7 8 9
D E A L E R C O D E
R E - E N T E R
CLEAR PROGRAM:
Should it be necessary to create a new custom default program, (a) from the Dealer Program Mode, press
C
to
enter the Address Program Mode; (b) access Location 2285 (Clear Program) or 2286 (Cold Start); (c) press
U
and then (d) press
C
to
exit the Dealer Program Mode. A “
SYSTEM TROUBLE/E09-00 SERVICE
” will occur. Press
C
to silence the programmer.
Clear Dealer Program (Erases Dealer Program)
Use this feature to erase the Panel Program, while maintaining Scheduled Data and Zone Descrip-
tions. Access address 2285 and press
U
. Data entry is not allowed.
NOTE:
Enter Easy
Menu Driven Program Mode to reprogram system.
Cold Start (Erases Entire Program)
This erases all programmed data (Dealer Program, Zone Description Data and Schedules).
Access address 2286 and press
U
. Data entry is not allowed.
NOTE:
Some features
(schedules) can only be programmed again with the Downloading Software.
DATA
ENTRY
AUX 1/AUX 2
OPTIONS
0
None
1
Relay Group 1 Toggle
2
Relay Group 2 Toggle
9
Keypad Panic
A
Keypad Aux.
B
Instant
C
PGM2 Ouput Toggle
D
Access on PGM2 Output
E
Arm STAY
F
Interior Button
(Direct Entry)
0 1 -
EXIT DEALER PROGRAM MODE:
This completes the custom default program. Press
C
to enter the Direct Address Program
Mode for further programming or press
C
once again to end all programming.
2 2 8 5 X X H
2 2 8 6 X X H
T E S T T I M E R
S M T W T F S H H : M M
Enter Zone Descriptions
•
For each zone, enter a description of up to two lines. Press
U
to save each description.
•
See next page for instructions for entering characters and numbers for the zone descriptions.
•
To proceed to the next description, place the cursor under the Zone Number (e.g. “1”) and press the
number that corresponds to the zone. Program new description as above.
Enter Date
(Press
R
to set cursor).
•
Enter the current date in the format MM/DD/YY. (MM = month, DD = day and YY = year.
•
Press
U
to save. Press the
NEXT/YES
button to proceed.
Enter Time
(Press
R
to set cursor.)
•
Enter the current time in format HH:MMA/P, where HH=hours (01–12); MM=minutes (00–59).
•
Select AM or PM by pressing any number button.
•
Press
U
to save. Press the
NEXT/YES
button to proceed.
Dealer Code
•
Directly enter the Dealer Code (default = 456789), using
0
through
9
buttons.
•
Press
U
to save. Re-enter the Dealer Code to verify the previous code. Press
U
to save.
•
Press the
NEXT/YES
button to proceed.
Test Timer
•
Select day(s) by simply erasing the unwanted days. Move the cursor over the day and press any
number key to erase/restore the day. For example, "Monday" and "Friday" will appear as: "•
M
•
•
•
F
•"
•
Enter Time (in 24 hour format) by moving cursor under the left H and pressing two digits to overwrite
the existing default of 00.
Note:
Midnight is 00:00. Enter minutes by continuing to enter data or if
just updating minutes move the cursor under the left M and enter the two digits to overwrite the exist-
ing default of 00. Use
R
as right cursor one position.
E
A
SY MEN
U
DR
IVEN
PRO
G
RA
M
MOD
E