L
NAPCO Security Systems
Freedom F-64 Programming Instructions
Page 15
WI1502A 9/06
vance to the data field.
5. Press
015
. The numbers 015 will appear on the programmer display indicating the number
of seconds entered.
6. Press
U
to save. Address 1417 is now programmed with a 15-second Abort Delay.
7. Press
R
and enter another 4-digit address to continue programming--or--press
C
to exit.
C) Hexadecimal Format Example
Data such as Report Codes displays and accepts data by means of a Hexadecimal display. Data is entered di-
rectly, by pressing keys 1 – 9,
G0
for zero, and
G1
through
G5
for hex B through F (11-
15), with the cursor automatically moving to the right upon key press. See table below.
EXAMPLE: HEXADECIMAL Format with the F-64PROG:
Program
Chime Timeout
to be 2 seconds.
DETERMINE THE DATA ENTRIES
1. Referring to SYSTEM DELAYS & TIMEOUTS in the Programming Worksheets that follow, the Chime Timeout
is located at address 1418. In the "
Chime Timeout Options
" table, the data entries needed to assign a time-
out of 2 seconds are "blank" and "8".
ENTRY
TOTAL
PRESS
KEYPAD
DISPLAYS
ENTRY
TOTAL
PRESS
KEYPAD
DISPLAYS
blank
0
•
8
8
8
1
1
1
9
9
9
2
2
2
10
G0
0
3
3
3
11
G1
B
4
4
4
12
G2
C
5
5
5
13
G3
D
6
6
6
14
G4
E
7
7
7
15
G5
F
HEXADECIMAL ENTRIES
CHIME
ADDRESS 1418
TIMEOUT
(¼sec.)
[Default = 2 ¼sec. = ½ sec.]
DATA ENTRY LOCATION:
Decimal Format
•
No time yet entered
DATA ENTRY LOCATION:
Decimal Format
Press
0
8
in order to set "Chime
Timeout" to 2 seconds. The "H" on the right
indicates "Hexadecimal" format.
Address
1418
"Chime
Timeout"
1418 - - H
1418 - 8 H
Address
1418
"Chime
Timeout"
2 seconds
CHIME TIMEOUT OPTIONS
TIMEOUT
LEFT
RIGHT
blank (•) blank (•)
0
x
¼sec. = 0 sec.
blank (•)
2
2
x
¼sec. = ½ sec.
blank (•)
3
3
x
¼sec. = ¾ sec.
blank (•)
4
4
x
¼sec. = 1 sec.
blank (•)
5
5
x
¼sec. = 1.25 sec.
blank (•)
6
6
x
¼sec. = 1.5 sec.
blank (•)
7
7
x
¼sec. = 1.75 sec.
blank (•)
8
8
x
¼sec. = 2 sec.
F
F
255
x
¼sec. = 63.25
DATA ENTRIES
DI
RECT A
D
DRESS PROGRA
M
MODE