L
NAPCO Security Systems
Freedom F-64 Programming Instructions
Page 29
WI1502A 9/06
Enable Keypad Options
Enable Keypad Options
ADDR
Keypad
Fire
Keypad
Aux.*
Keypad
Panic
RSRVD
Ambush
Easy
Arming
Panel
Access
RSRVD
1
2
3
4
5
6
7
8
Keypad 1 Options
1440
ON
ON
ON
Keypad 2 Options
1441
ON
ON
ON
Keypad 3 Options
1442
ON
ON
ON
Keypad 4 Options
1443
ON
ON
ON
Keypad 5 Options
1444
Keypad 6 Options
1445
Keypad 7 Options
1446
[Default = blank (•) from address 1440-1446, except where specified in table above]
* NOTE:
Keypad Aux. is not to be selected for UL Installations.
KEYPAD OPTIONS (ADDRESS 0723-0736 & 1055-1058)
KEYPAD/TOUCHPAD OPTIONS (ADDRESS 1425-1431, 1440-1446)
Enable Keypad/Touchpad
Type & Activation
ENABLE TYPE
AREA ASSIGNMENT
ENABLE TYPE:
Up to 7 key-
pads/Touchpads may be pro-
grammed, if they are connected.
NOTE:
See Touchpad Configu-
ration Mode (see page 40).
1.
Select keypad/Touchpad type
for each keypad from the
tables shown.
2.
Enter data in corresponding
address locations.
3.
Press
U
to save.
ADDR
Blank (•) = Burg Keypad
2 = Wizard *
*Not for UL Installations
Blank (•) = Disabled
1 = Area 1, 2 = Area 2,
3 = Area 3, 4 = Area 4
Keypad/Touchpad 1
1425
1
Keypad/Touchpad 2
1426
Keypad/Touchpad 3
1427
Keypad/Touchpad 4
1428
Keypad/Touchpad 5
1429
Keypad/Touchpad 6
1430
Keypad/Touchpad 7
1431
[Default = 1 for address 1425; blank (•) from address 1426-1431]
ENABLE KEYPAD OPTIONS:
Select options for any of the 7 keypads.
1. Select the desired option entering the option number (1-8) for each digit.
2. At the F-64PROG programmer, enter corresponding option number in address location.
NOTE:
Dark shaded data value
box shows option not available. Press
U
to save.
MAPPING F-64TP DOORS AND PIR'S (ADDRESS 2090-2101)
Keypad address programming locations for mapping F-
64TP Doors and PIR's to the F-64 control panel are dis-
played in the table at right:
In addition, in order for the F-64TP to function correctly
on the F-64 panel, the following programming / installa-
tion rules are required:
1. A F-64TP must be wired and addressed as Key-
pad #1 for any F-64 Touchpads to work on the
system.
2. Must program (map) at least 1 Door Zone and a
PIR for each F-64 Touchpad.
3. All PIR's in the system, including the mapped Inte-
gral F-64 Touchpad PIR, must be programmed as
interior to allow conversion from arming Stay to
Away.
4. All zones programmed for interior must also be
programmed for Auto Bypass.
Enable Keypad Options
MAPPING F-64TP Doors and PIR's
ADDR
Zone #
(1-64)
Zone # of F64TP # 1 Door/Bolt TX #1
2090
9
Zone # of F64TP # 1 Door/Bolt TX #2
2091
10
Zone # of F64TP # 1 PIR
2092
11
Zone # of F64TP # 2 Door/Bolt TX #1
2093
Zone # of F64TP # 2 Door/Bolt TX #2
2094
Zone # of F64TP # 2 PIR \
2095
Zone # of F64TP # 3 Door/Bolt TX #1
2096
Zone # of F64TP # 3 Door/Bolt TX #2
2097
Zone # of F64TP # 3 PIR
2098
Zone # of F64TP # 4 Door/Bolt TX #1
2099
Zone # of F64TP # 4 Door/Bolt TX #2
2100
Zone # of F64TP # 4 PIR
2101
[Default = blank (•) from address 2090-2101]
5. Exit Delay time must first be programmed to allow conversion from arming Stay to Away.
1. Select the desired zone by entering the zone number (001-064) for each address.
2. At the F-64PROG Programmer, enter corresponding zone number in address location. Press
U
to save.
DI
RECT A
D
DRESS PROGRA
M