![NANOTEC PD4-C Technical Manual Download Page 212](http://html1.mh-extra.com/html/nanotec/pd4-c/pd4-c_technical-manual_3241514212.webp)
9 Description of the object dictionary
Change history
Value description
Subindex
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
read only
PDO mapping
no
Allowed values
Preset value
02
h
Subindex
01
h
Name
DeltaSpeed
Data type
UNSIGNED32
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
000001F4
h
Subindex
02
h
Name
DeltaTime
Data type
UNSIGNED16
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
0001
h
Description
The deceleration is specified as a fraction in user-defined units:
Speed change per change in time.
Subindex 01
h
: Contains the change in speed.
Subindex 02
h
: Contains the change in time.
604Ah Vl Velocity Quick Stop
Function
This object defines the deceleration (deceleration ramp) if the Quick Stop state is initiated in velocity mode.
Object description
Index
604A
h
Object name
Vl Velocity Quick Stop
Object Code
RECORD
Version: 2.0.1 / FIR-v1650
212