![NANOTEC PD4-C Technical Manual Download Page 141](http://html1.mh-extra.com/html/nanotec/pd4-c/pd4-c_technical-manual_3241514141.webp)
9 Description of the object dictionary
Object name
Encoder Configuration
Object Code
VARIABLE
Data type
UNSIGNED32
Savable
yes, category: tuning
Access
read / write
PDO mapping
no
Allowed values
Preset value
00000000
h
Firmware version
FIR-v1426
Change history
Firmware version FIR-v1614: "Savable" entry changed from "yes,
category: application" to "yes, category: tuning".
Description
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
TYPE
TYPE
Defines the type of encoder. For a differential encoder, the bit must have the value "0". For a single-
ended encoder, the bit must be set to "1".
205Ah Encoder Boot Value
Function
Tip
This object only has a function when using an absolute encoder. If an absolute encoder is not used,
the value is always 0.
The initial encoder position when switching on the controller (in user-defined units) can be read from this
object.
Object description
Index
205A
h
Object name
Encoder Boot Value
Object Code
VARIABLE
Data type
UNSIGNED32
Savable
no
Access
read only
PDO mapping
no
Allowed values
Preset value
00000000
h
Firmware version
FIR-v1446
Version: 2.0.1 / FIR-v1650