9 Description of the object dictionary
Description
The subindices have the following function:
●
01
h
: If the value 746F6F62
h
is entered here, the firmware is rebooted.
●
02
h
: Time in milliseconds: delays the reboot of the firmware by the respective time.
●
03
h
: Bit 0 can be used to switch short circuiting of the motor windings in boot loader mode off and on:
○
Bit 0 = 1: Short circuiting of the motor windings in boot loader mode is switched off.
○
Bit 0 = 0: Short circuiting of the motor windings in boot loader mode is switched on.
3202h Motor Drive Submode Select
Function
Controls the controller mode, such as the changeover between closed loop / open loop and whether Velocity
Mode is simulated via the S-controller or functions with a real V-controller in closed loop.
Object description
Index
3202
h
Object name
Motor Drive Submode Select
Object Code
VARIABLE
Data type
UNSIGNED32
Savable
yes, category: drive
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
●
PD4-C5918M4204-E-01: 00000000
h
●
PD4-C6018L4204-E-01: 00000000
h
●
PD4-CB59M024035-E-01: 00000040
h
●
PD4-C5918L4204-E-01: 00000000
h
●
PD4-C5918X4204-E-01: 00000000
h
Firmware version
FIR-v1426
Change history
Firmware version FIR-v1540: "Savable" entry changed from "yes
category: application" to "yes, category: travel".
Firmware version FIR-v1540: "Savable" entry changed from "yes
category: travel" to "yes, category: movement".
Firmware version FIR-v1650-B527540: entry "Savable" changed from
"yes, category: movement" to "yes, category: drive".
Description
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
Torque
7
6
5
4
3
2
1
0
BLDC
VoS CL/OL
CurRed Brake
CL/OL
Changeover between open loop and closed loop
●
Value = "0": open loop
Version: 2.0.1 / FIR-v1650