© by N&W GLOBAL VENDING S.p.A.
41
07 - 2010 3375 - 01
D
osEr
1 - 9 f
aulT
If the current input of the ingredient motor should fall
outside the range of default values, all the selections
involving that doser will be disabled.
W
HippEr
1 - 6 f
aulT
If the current input of the whipper motor should fall
outside the range of default values, all the selections
involving that whipper will be disabled.
p
ump
1 - 7 f
aulT
If the current input of a pump should fall outside the
range of default values, all the selections involving that
pump will be disabled.
sugar/stirrer fault
If the current input of the direct current motor should fall
outside the range of default values, this failure is dis-
played. sugarless drinks can be dispensed.
s
HorT
c
ircuiT
m
osfET
the machine fails if a device intended to control direct
current motors on the actuation board (mosfet) remains
active.
s
HorT
c
ircuiT
this failure is displayed if the software should detect a
short-circuit on one of the direct current motors connect-
ed with the actuation board. a failure may be simultane-
ously detected on one of the direct current motors.
s
ugar
/s
TirrEr
f
aulT
If the current input of the direct current motor should fall
outside the range of default values, this failure is dis-
played. sugarless drinks can be dispensed.
W
aTEr
f
ailurE
the water failure is declared during the v.m. standby if
the water inlet solenoid valve is operated for over 20”.
If a water failure is available, you can manually restore
the service by pressing a key of the pushbutton panel.
the water inlet solenoid valve is supplied for max. 20”; if
the level is not reached, the solenoid valve is closed and
the water failure is signalled once again.
Wait 30 minutes before making another 2 attempts to
restore. at the 4th attempt, the solenoid valve is perma-
nently inhibited (now, power off / on the machine to be
able to make another 3 attempts or to reset the failure
from the programming menu).
c
olD
prEssurE
sWiTcH
For models with a cold unit only.
Cold selections are disabled if the pressure switch at the
network inlet signals no water.
c
olD
comprEssor
For models with a cold unit only.
to signal that the cold unit compressor is not properly
working.
N
o
syrup
1
aND
2
For models with a cold unit only.
the syrup used in selections is used up.
the selections based on used-up syrup are disabled.
N
o
carBoNaTor
For models with a cold unit only.
the level control device signals that the carbonator is
empty: cold selections are set out of order.
c
olD
uNiT
BoarD
For models with a cold unit only.
It signals that the control board of the control unit is not
properly working.
r
EsET
Confirm the function to reset all current failures, if any.
f
ailurE
HisTory
filE
You can display the latest 16 failures, from the most
recent to the most remote one, by pressing scroll key
�
and
�
. Moreover, the display will show the tripping date
and time and whether the failure is still active or not (on
/ OFF/), similarly to the data in the EVADTS data audit.
Summary of Contents for Canto Plus Instant
Page 2: ......
Page 5: ......
Page 6: ......
Page 60: ...sx48501 TZ...
Page 61: ...Canto SCHEMA ELETTRICO WIRING DIAGRAM ALIMENTAZIONE POWER SUPPLY TZ...
Page 62: ...sx48701...
Page 63: ...Canto SCHEMA ELETTRICO WIRING DIAGRAM PORTA DOOR...
Page 64: ...sx48501...
Page 65: ...Canto SCHEMA ELETTRICO WIRING DIAGRAM MACCHINA INSTANT INSTANT MACHINE...
Page 68: ......