OPERATION OF A NANAWALL CSW75 – FOLDING 
CENTER PIVOT FRAMELESS SYSTEM

 

For opening and closing the folding center pivot frameless 
system, please observe the special notes on the following 
pages in as far as they relate to your unit. 

When operating the system similar to any other 
door, please do not place your fingers between 
the panels/pivot points. Be very careful when 
you operate the panels and avoid glass to glass 
contact between the panels!!

Only properly trained personnel should operate the unit. 
No children should operate the unit.

Do not force the system if not operating properly. If you

 

encounter any difficulties in operating the unit, please

 

have it inspected by a NanaWall 

C

ertified 

I

nstaller as 

soon as possible.

The correct sequence of opening and closing of panels is 
dependent on the configuration ordered. Panels must be 
opened and closed in the right order in a gentle manner.

Opening and Closing a Unit.

1.

If available, please open the single/double action end
panels, first.

2. Disengage all of the locking points on each folding

panel. Operation of each type of lock as follows:

a. Profile Cylinder – turn with key or thumb turn.
b. Quick Release Lock – pull knob and lift up/down.

3. Now you can open the folding panels by slightly

pushing against 2 adjacent panels from the front,
where the hinge part with hinge pin is located in your
direction. The panels fold together and you can push
them gently from the side using both hands.

4. Note that there is a carrier at each upper center of a

folding panel and no guide at the bottom that could
prevent the panels from swaying. Do not move more
than 4 panels at a time.

5. When you have a swing panel attached to a folding

panel with carrier, make sure that you open the swing
panel 180°, first and keep it in this position when you
fold the panels to the side.

6. Do not force. Avoid any pendulum movements,

otherwise the bottom rail could damage the floor.

7.

If there are more panels stacking to one side or both
sides (left/right with up to 4 panels), please be sure to
handle the chain of panels with care and fold them to
the correct side.

8. For closing, please proceed in reversed order as

described above. To pull the panels from the stacked
position, you will need to grasp the first panel
by the edges with both hands as high as possible.
Move evenly and keep panels as vertical as possible.
Avoid any pendulum movements.

9. Make sure each folding panel is placed in its proper

position in the opening and engage the locking point
before moving the next panel. Do not place your
fingers between the panels/ pivot points. Do not force
any locking point.

10. For units with multiple panels folding to one side

or both sides (left/right with up to 4 panels), make
sure that each chain of panels is placed in its proper
position in the opening and engage all locking points
before moving the next chain of panels.

Summary of Contents for CSW75

Page 1: ...75 Folding Center Pivot Frameless System This manual is to be used by the installer for installation and is to be kept by the Owner for reference Replacement parts can be ordered directly through Nana...

Page 2: ...ckness for the panels is based on the Glass Association of North America GANA recommended minimum glass thickness for fully tempered Interior butt glazed fixed glass panels The CSW75 system is shipped...

Page 3: ...anel 1 folding center pivot panel Panel 2 folding center pivot panel Panel 3 folding center pivot panel Panel 4 folding center pivot panel Panel 5 single double action end panel with pivot box or sing...

Page 4: ...taller than the total unit height depending on how level the support structure above is See Sheet 2 of the Installation Manual It is important that the opening be the correct size Product performance...

Page 5: ...nd floor sockets in concrete slabs and wood the substrate should be a minimum of 4 thick these components should be fully embedded into the concrete or wood and the clear edge distance in concrete or...

Page 6: ...ener spacing in the support structure within the opening depends on substrate material design windload pressures if exterior of project panel height and other requirements of the project All anchoring...

Page 7: ...D Step B1 Check all the carriers on all the folding panels Make sure all the locking nuts are securely tight Do not make any adjustments on the carriers yet Step B2 Before inserting the panels remove...

Page 8: ...ross the width of the opening and 23 mm 7 8 at the top If the gaps are not correct then adjust the upper track by removing or adding shims above the head track as needed The upper track has to be perf...

Page 9: ...ing with pivot point the dimension for the center of the pivot axle to the adjacent edge of the panel end cap should be 1 11 16 43 mm plus the additional 3 16 4 mm for the gap to the wall Please check...

Page 10: ...chisel out the concrete to recess the floor closer into the floor Make sure that the full underside of the box rests on a flush and level surface and fix it temporarily into place Then install the top...

Page 11: ...oint of the pivot panel use suitable material to finally fix the floor closer in place Before you put on the cover for the floor closer make sure to measure how much to cut off to make it fit with the...

Page 12: ...nt where the hinge part with hinge pin is located in your direction The panels fold together and you can push them gently from the side using both hands 4 Note that there is a carrier at each upper ce...

Page 13: ...cally check for worn or damaged components and replace as soon as possible A unit with nonworking components will subject the other components to increased stress and lead to premature failure A unit...

Page 14: ...s thickness and specifications will be needed Depending on the model widths of frameless all glass panels may not be equal Ask NanaWall for the glass dimensions Please note that glass is required to b...

Page 15: ...ance For Coastal Salt Water and Other Extreme Environments included in the Owner s Manual for each Product and is available for review on NanaWall s website is properly implemented and documented An E...

Page 16: ...ent part or product is not commercially practicable NanaWall may elect to refund the purchase price of the affected product in full satisfaction of its obligations Wood Wood components must be properl...

Page 17: ...application storage handling modification or waterproofing Movement of surrounding substrates including deflection of the header of more than or any other stresses on product Improper installation fla...

Page 18: ...tions beyond NanaWall s control Gas fill or retention levels in insulated glass units Field testing of Product Performance of the Product in conformance to any published NanaWall testing results e g a...

Page 19: ...___________________________________ Project Address if different from above _____________________________________________________________ INSTALLATION Installer Name _______________________________ Ad...

Reviews: