![NAL RESEARCH CORPORATION A3LA-RM General Description Manual Download Page 76](http://html2.mh-extra.com/html/nal-research-corporation/a3la-rm/a3la-rm_general-description-manual_3148302076.webp)
NAL Research Corporation (451-93156-002A)
76
commands. Instead, the A3LA-RM will continuously dial the number that is setup for auto
dialing. The ^ADR command controls the retry delay in between dial attempts.
<enabled>:
0 Do not auto dial when the DTR line is low (default)
1 Auto dial when the DTR line is low
<number>: The phone number to dial. The number must be enclosed in double quotes and
cannot be more than 20 characters long.
A.8.122 ^ADR – Auto Dial Retry
Exec Command: ^ADR=<delay>
This command sets the time to delay in between dial attempts in auto dial mode.
<delay>: The number of seconds to delay. The value must be between 5 and 255 seconds.
A.8.123 ^CCOP – Change Crypto Officer Password (Encryption)
Exec Command: ^CCOP=<old>,<new>
Change the Crypto Officer’s password from factory-set/old value to new value. The password
must include all printable keyboard characters. The password will not be reset by AT command
&F. When the A3LA-RM is set to echo, all entries are replaced with asterisks (*) instead of the
actual typed value. All passwords must be between 8 and 16 characters in length. The factory-
set password is ‘temp password’ and must be changed before encryption can be used.
<old>: Old password and must be enclosed by two single quotes (‘old password‘)
<new>: New password and must be enclosed by two single quotes (‘new password‘)
A.8.124 ^CMGEC – Clear SMS Encrypted Storage
This command is a synonym for ^SMSE for backward compatibility. See the ^SMSE command
for details.
A.8.125 ^FFW – Flash Firmware
Exec Command: ^FFW
Puts the firmware into flashing mode
A.8.126 ^KD – Key for Decryption (Encryption)
Exec Command: ^KD=<password>,<key>
Allow entering the 32 bytes for the AES decryption key. These bytes must be entered with
mandatory leading 0s, where each byte is represented by 2 hexadecimal uppercase characters
for a total of 64 digits. The password and key will not be reset by &F. The password and key will
not be echoed. This command must be entered twice before an update is made.
NOTE: The decryption key must match the encryption key at the base station or network
operation center (NOC).
NOTE: A decryption key of all 0s and a TBR (Time Between Reports) value of 64801 will cause
requested reports not to be sent out in tracking mode.
<password>: The Crypto Officer Password must be enclosed by two single quotes (‘ ‘). The
Crypto Officer Password must be changed from its factory-set value before this
command will work.