![NAL RESEARCH CORPORATION A3LA-RM General Description Manual Download Page 53](http://html2.mh-extra.com/html/nal-research-corporation/a3la-rm/a3la-rm_general-description-manual_3148302053.webp)
NAL Research Corporation (451-93156-002A)
53
0:
Buffer(s) cleared successfully
1:
An error occurred while clearing the buffer(s)
A.8.89 +SBDC – Short Burst Data: Clear SBD MOMSN
Exec Command: +SBDC
This command will clear (set to 0) the mobile originated message sequence number (MOMSN)
stored in A3LA-RM.
The MOMSN is maintained even after power cycle.
Command Response:
0: The MOMSN was cleared successfully
1: An error occurred while clearing the MOMSN
A.8.90 +SBDS – Short Burst Data: Status
Exec Command: +SBDS
This command returns current state of the mobile originated and mobile terminated buffers.
Command Response: +SBDS: <MO flag>, <MOMSN>, <MT flag>, <MTMSN>
where:
<MO flag>: The MO flag indicates the existence of a message in the mobile originated buffer.
The response from the A3LA-RM is one of the following numeric codes:
0:
No message in mobile originated buffer
1:
Message in mobile originated buffer
<MOMSN>: The MOMSN identifies the sequence number that will be used during the next
mobile originated SBD session.
<MT Flag>: The MT flag indicates the existence of a message in the mobile terminated buffer.
The response from the A3LA-RM is one of the following numeric codes:
0:
No message in mobile terminated buffer
1:
Message in mobile terminated buffer
<MTMSN>: The MTMSN identifies the sequence number that was used in the most recent
mobile terminated SBD session. This value will be –1 if there is nothing in the mobile
terminated buffer.
A.8.91 +SBDTC – Short Burst Data: Transfer MO Buffer to MT Buffer
Exec Command: +SBDTC
This command will transfer the contents of the mobile originated buffer to the mobile
terminated buffer. Developers of DTE can use this command to test reading and writing to the
A3LA-RM without actually initiating SBD sessions with the ESS.
Command Response:
0:
Mobile originated buffer transferred successfully
1:
An error occurred while transferring the mobile originated buffer
A.8.92 +CAR – Audio Output Control
Set Command: +CAR=<n>