These parameters are specified by bit. The items specified in these parameters
are the followings.
( Binary form )
Motion direction
bit0 0 : Turn ON for + direction
Deviation counter
bit1 0 : Turn ON for homing is completed.
Driver error
bit2 0 : An error is detected in the energized
condition.
Near home
bit3 0 : Near home position in the energized
condition.
Home
bit4 0 : Home position in the de-energized condition.
Overlimit
bit5 0 : Overlimit position in the de-energized
condition.
I/F logic
External input ( E-type
only )
bit6 1 : Input is valid in the energized condition.
(1)00000
*1 :
The default values are values at the time of shipment, when [
Initialize
] button is pressed, or when a new
file is created.
*2 :
Acceleration / deceleration time is 64 to 4,999 if positioning unit E-type is ver. 1.1 or earlier.
4-5