Troubleshooting
9-64
(00400)
Warning Message
Details
Response
A
Memory protected.
AUTOVIEW=AUTO
Memory protected with the
auto view function
Erase the recorded video
Turn OFF the auto view function
Memory protected. REC
MODE=****
Memory protected with the
auto segment switch AUTO
setting
Erase the recorded video
Change the settings for the
recording method
No Battery.
The memory backup battery
is not installed
The camera may be malfunctioned.
Please contact a NAC's authorized
distributor/sales rep in your
region.
-
Power Drop Detected.
*******
Input power source is
unstable (intermittent
outages)
If AC POWER SYSTEM used
→
Turn
off the power to the camera and
AC adapter and contact us.
-
RTC battery is low power!
RTC battery dead
Contact us for RTC battery
replacement
-
Old date setting
If set to date before 2003
→
Set
to the current date
If connected to PC set to date
before 2003 using HXLink
→
Set
the date on the PC (read the
HXLink user’s guide for details)
Saving failure!
Can’t save on USB /CFast
media
USB/CFast device is not operating
properly (compatibility issue)
→
Use a different media
-
Sensor temperature is
outside the range.
Abnormal sensor
temperature
If the ambient temperature is high
→
Use within the guaranteed
operating temperature range. Do
not place unit near strong light or
heat.
If the vents are blocked
→
Check
the position of the vents and
make sure they aren’t blocked
Summary of Contents for ST-839
Page 2: ......
Page 16: ...Table of Contents 14 00400 11 Index Index 11 2 ...
Page 23: ...Exterior View and Names of Each Part 1 7 00400 1 Lens mount A 2 3 Front and Back 1 ...
Page 45: ...Turning the Power ON OFF 2 17 00400 6 Connect the cable to the HX 7 ...
Page 56: ...J PAD3 Operation 3 10 00400 ...
Page 90: ...Lens Control 3 44 00400 Hold switch Temporarily disables operation from the J PAD3 ...
Page 98: ...3 52 00400 ...
Page 188: ...5 16 00400 ...
Page 202: ...6 14 00400 ...
Page 220: ...7 18 00400 ...
Page 318: ...9 66 00400 ...
Page 360: ...Figures Figures 10 42 00400 MEMRECAM HX 7 Camera Unit Dimensional Figure ...
Page 361: ...Figures 10 43 00400 AC Adapter Dimensional Figure ...
Page 362: ...10 44 00400 ...
Page 363: ...11 1 00400 11 Index Index 11 2 ...
Page 370: ...Index 11 8 00400 Y YC TIFF 7 14 Z ZOOM 5 4 6 5 ...