GT20 Wire and Programming Manual
www.NabcoEntrances.com
P/N C-00140
Rev 5-7-18
Element
Default
Value
Description
LockAU
UNLOCK
UNLOCK/
LOCK
X
X
Sets the condition of the lock when in Automatic mode.
X
X
Only visible when Unlock is set to PERMAN
LockEX
LOCK
UNLOCK/
LOCK
X
X
Sets the condition of the lock when in EXIT mode.
X
X
Only visible when Unlock is set to PERMAN
LockMA
UNLOCK
UNLOCK/
LOCK
X
X
Sets the condition of the lock when in MANUAL mode.
X
X
Only visible when Unlock is set to PERMAN
LcdDir
0
0...1
Orientation of the display (LCD direction)
MovCon
OFF
OFF/ON
Endurance test Open/Close (moving continuous)
Pre Sen
N.C.
OFF/N.C./
N.O.
Swing side presence sensor output logic
OExMAN
ON
OFF/ON
X
X
ON” enables activation to reopen the door during the closing cycle of a manual opening.
X
X
OExMAN only if APuGo is turned OFF.
The following Table is only displayed when an optional Relay Board is installed
RC 0.1
RC 0.2
RC 0.3
RC 0.4
CLOSED
OPEN
ERROR
GONG
Only (1) PCB Terminal per Switch Activation is allowed. For example (2) activations (during closing and
opening) must be wired to (2) different PCB Terminals.
Note: The Configurator Menu will only display the following Elements/Values when the Relay PCB
Board is intalled.
Note: NABCO does not install more than (1) Relay PCB Board.
CLOSED
Relay switches when the Door Panel is fully closed.
OPENING
Relay switches when the Door Panel is opening.
OPEN
Relay switches when the Door Panel is fully open.
CLOSING
Relay switches when the Door Panel is closing.
ERROR
Relay switches if the GT20 Control detects an Error(s).
PSAUTO
Relay switches when the Program Selector is in Mode: AUTOMATIC
PSNIGHT
Relay switches when the Program Selector is in Mode: NIGHT
PSEXIT
Relay switches when the Program Selector is in Mode: EXIT
PSOPEN
Relay switches when the Program Selector is in Mode: OPEN
PSMANU
Relay switches when the Program Selector is in Mode: MANUAL
GONG
Relay switches
momentarily
during the time the GT20 Control recieves a signal from:
Terminal 12 and Terminal 13 (Opening Command Inside).
LOCKED
Relay switches during the time the Door Panel is LOCKED with an electric lock.
Table 12
Double Door Menu: Simultaneous Pairs and Astragal Pairs
Element
Default
Value
Description
DubleD
OFF
MastrA
SlaveA
Determines closing sequence in case of Simultaneous Pair with Astragal.
AoSeq
0
0...110
X
X
Delay angle for opening sequence for Slave Door.
X
X
Only visible on Slave Control when DubleD is not OFF
AcSeq
0
0...110
X
X
Delay angle for closing sequence for Master Door.
X
X
Only visible on Master Control when DubleD is not OFF
TcSeq
1.5
0...3.0
X
X
Time delay for closing sequence for Master Door.
X
X
Only visible on Master Control when DubleD is not OFF
InterL
OFF
OFF
Side A
Side B
Two individual door Panels that are connected by CAM Bus. One Door Panel cannot open if
the other door is open. Also known as AirLock or Mantrap.
ILAuto
Active
Active
Inactive
X
X
Airlock functionality works in Automatic mode.
X
X
Only visible if InterL is not OFF