SECTION 9 .2: Menu Selection
Table 9
Menus
Menu
Description
PARAMETER
Sets the parameters for Swing door movement.
CONFIG
Configuration: Sets the parameters of the GT20 Control Features and Functions.
DOUBLE DOOR
Sets the Closing sequence and Interlock function.
DIAGNOSTICS
Diagnostic Tools that display the status of various inputs.
ERROR ACTIVE
X
X
Displays Pending Active Errors.
X
X
Active Error list is updated with the latest additions appearing at the end.
X
X
A0 indicates the latest Active error.
HISTORY ERROR
X
X
Displays all Active Errors that were detected and then corrected or not corrected.
X
X
H0 indicates the latest Active error.
REINIT
Reinitialization resets Settings back to Factory Default
BLOCK?
Locks/Unlocks Joystick
UPDATE SW
Start the upgrade process from the USB Stick.
TEACH
X
X
Programs the Initial Setup, and finds Errors (if any).
X
X
Programs a new Setup Procedure when deemed necessary.
Table 10
Partameter Menu: Settings for Door Panel Movement
Element
Unit Type Default
Value
Description
Region
BOTH
EU
Eu or US
EU - Europe; US - United States
Software version determined by UL Standards. Must be changed to US.
Vo
Full Power
6
0..14
Opening speed (velocity open)
Low Energy
9
0...9
Vc
Full Power
4
0..14
Closing speed (velocity closed)
Low Energy
9
0...9
TOEx
Full Power
3s
0...60s
TOEx sets the hold-open time resulting from activation signals from devices
connected to: terminals 9+10 for exterior activation and terminals 12+13 for
interior activation.
Low Energy
5s
3...60s
ANSI 156.19 for Low Energy:
TOEx must be
no less than 5s.
TKey
Full Power
5s
0...180s
X
X
TKey sets the hold-open time resulting from an activation signal from a device
(referred to as KEY) on terminals 2+3.
X
X
With TOEx and TKey, you can set a different hold open times for different
activation devices by using different terminals.
Low Energy
5s
3...180s
TPuGo Full Power
3s
0...180s
Determines how long the Door Panel stays open.
Low Energy
3s
3...180s
TDelay Full & Low
0.2s
0.0...4.0s Tdelay sets the amount of time the door hesitates to allow the lock to release
before opening.
FDelay Full Power
OFF
OFF...7.0A Fdelay is a temporary “hold closed” force applied to the door to keep it closed
while the electric lock is being released. This parameter sets the amount of force
that is applied. FDelay is only active if TDelay setting is greater than 0.
Low Energy
OFF
OFF...7.0A
TLock
Full & Low
0.5s
0.0...4.0s Sets amount of time Door Panel will press against lock to engage it.
FLock
Full & Low
2.0A
OFF...7.0A Sets amount of force that is applied to the door to engage the lock at the closed
position. It is only active if TLock setting is greater than 0.
FSlam
Full & Low
OFF
OFF...10
Accelerating function (force slam). For example: When a door panel needs to be
forced shut due to a latch or heavy seals.