4. GENERAL INSTALLATION LAyOUT GUIDE
Plan your installation carefully. Check on
the nearest and most accessible rising
main water supply, this may be beneath
the bath or in the loft, where it feeds the
water storage tank. Use only the cold
rising water main.
Avoid connecting the shower unit if
possible where it will be affected by water
drawn off by another appliance. For
example from the mains feed to the toilet
as this may cause a drop in pressure to a
level that is too low for the shower unit to
work correctly.
A WRAS (water regulations advice
scheme) listed isolating valve must be
fitted between the rising main and the
unit to comply with water regulations and
to allow for routine maintenance and
servicing.
BATH
COLD WATER
MAINS SUPPLY
SEPARATE PERMANENTLY
CONNECTED SUPPLY
FROM CONSUMER UNIT
ISOLATING
STOP TAP
DOUBLE POLE
HEATER SWITCH
WALL MOUNTED
IN ACCORDANCE
WITH LOCAL
AUTHORITY
REGULATIONS
SHOWER
UNIT
BATHROOM
FLOOR
CEILING JOISTS