10. ChANGING ThE OPERATIONAL ShOWER PROGRAMMES
The shower has
four separate
operational programmes
which can be
adjusted on installation via a series of DIP
switches located on the display PCB. This
is mounted on the back of the front cover
as shown above.
The programmes are:
1. Audible feedback
to confirm user
command.
2. Maximum shower outlet
temperature lock
to provide three
MAXIMUM shower outlet temperature
settings.
3. Automatic timed off operation:
four settings are available.
4. Shower start temperature
can be
set to a FIXED 40 ºC (display digit 8 on
the seven segment temperature display)
or MEMORY – with start up temperature
as per the last shower. A double bleep
confirms to the user when the outlet
temperature has been reached.
IMPORTANT: The Thermostatic Care
models are factory set in BEAB Care
mode with settings as follows:
• the audible feedback is ON (single bleep
on each push button command)
• maximum temperature lock set
to PROGRAMME 1. This limits the
maximum temperature selectable by the
user to 41 ºC at digit 9 on the numerical
temperature indicator.
• automatic timed STOP feature set at the
maximum duration of 30 minutes.
• shower start temperature set at a FIXED
40 ºC.
NOTE:
DIP switch is ON when slider
switch in the upper position. DIP switch
is OFF when slider switch is in the
lower position.
ON
DIP
1 2 3 4 5 6
ON
DIP
1 2 3 4 5 6
SOUND
SWITCH
MAX
TEMP
RUNNING
TIME
TEMP
START
SOUND
SWITCH
MAX
TEMP
RUNNING
TIME
TEMP
START
DEFAULT SETTINGS –
ThERMOSTATIC CARE
Sound:
ON
Maximum temperature:
PROG 1
(30–41 ºC)
Running time:
30 MINS
Temperature Start:
FIXED
(nominal 40 ºC)
DEFAULT SETTINGS –
ThERMOSTATIC PLUS
Sound:
ON
Maximum temperature:
PROG 3
(30–47ºC)
Running time:
30 MINS
Temperature Start:
MEMORy