background image

3

PACK CONTENTS

Please make sure ALL 

components are included 

before starting the 

installation.

1.  Shower Unit
2.  Shower Handset
3.  Riser Rail Tube
4.  Riser Rail Brackets x2
5.  Riser Rail Height Adjuster
6.  Flexible Shower Hose
7.  Soap Dish
8.  Hose Retaining Ring
9.  Screw Packs
10.  Installation and User 

Instructions plus   

Guarantee Card

Thermo Response

 

Temperature

START/STOP

Tem

per

atu

re

Flow 

•  1. Shower Unit

•  2. Shower Handset

•  6. Flexible  

  Shower Hose

•  4. Riser Rail Bracket

•   4. Riser Rail Bracket

•  3. Riser Rail Tube
•  5. Riser Rail  

  Height Adjuster

•  7. Soap Dish

•  8. Hose Retaining  

 Ring

•  9. Screw Packs

•  10. Fitting Instructions  

  &  Guarantee Card

Instantaneous Electric Shower

Installation Instructions

IMPORTANT!

This Step-by-Step guide should be given to the customer

after installation and demonstration.

Thermo Response

 

QI

Summary of Contents for Thermo Response QI

Page 1: ...Thermostatic Control Instantaneous Electric Shower Installation and User Instructions IMPORTANT ThisStep by Stepguideshouldbegiventothecustomer afterinstallationanddemonstration Thermo ResponseQI...

Page 2: ...ide for installers TheMXrangeofThermoResponseQIshower modelshavebeenspeciallydesignedforQuick Installation Bothwaterandelectricscanenterthe showerunitfrom8differentpositions Theunitis wiredinternallyt...

Page 3: ...ser Instructionsplus GuaranteeCard Thermo Response Temperature START STOP Temperature Flow 1 ShowerUnit 2 ShowerHandset 6 Flexible ShowerHose 4 RiserRailBracket 4 RiserRailBracket 3 RiserRailTube 5 Ri...

Page 4: ...ation 6 Electricalinstallation 7 Fittothewallandconnecttheshowersupplies 8 ONLYCommissiontheshowerinthewaydescribed 9 Fittingthefrontcoverandaligningthecontrols 10 Familiariseyourselfwiththeuseroperat...

Page 5: ...ered inside the unit because of an incorrectly fitted cover DO NOT place items such as soap shampoo or other such bottles on top of the unit as liquid could leak through the joint between the cover an...

Page 6: ...l to avoid the possibility of distorting the back plate and making the front cover a poor fit Exercise great care when using power tools near water The use of a residual current device RDC is recommen...

Page 7: ...eentherisingmain andtheunittocomplywithwaterregulationsandto allowforroutinemaintenanceandservicing BATH COLD WATER MAINS SUPPLY SEPARATE PERMANENTLY CONNECTED SUPPLY FROM CONSUMER UNIT ISOLATING STOP...

Page 8: ...ALL PositionyourshoweronthewallsothatitwillNOT beinthedirectwatersprayfromtheshowerhandset whenfixed Youmaywishtoconsidermountingtheunitsothat theshowerhandsetcouldbeusedoverasinkfor washinghair Thesh...

Page 9: ...ITIONINGGUIDE Showerunitcanbemounted eithersideofriserrail Heightof showerhead andshower tosuituser s requirements Mainscoldwatersupply eithertop bottom left rightorrearentry 25mmminimum Outlineofbath...

Page 10: ...syoucanseefromthe diagramrighttheshower unitcanbebothplumbed andwiredfrom8different positions n Topright n Topleft n Bottomright n Bottomleft n Rightside n Leftside n Rearright n Rearleft Removablecov...

Page 11: ...ateincorporatesintothelower rightandlefthandsideofthebackplateremovable trimsectionstoalloweasyaccesswhendecidingon andconnectingtothewatermainssupply Removethebottomrighthandsidecoverplategiving acce...

Page 12: ...unitissuppliedwith2 separatesetsofconnectingterminalblocksmounted ontheshowerbackplatesothattheshowercanbe wiredforleftorrightinstallationswithminimum effort ONLYconnecttooneoftheterminalblocks Thedia...

Page 13: ...retoensurethattheretaining screwsareVERYtightcouldresultinafailureofthe terminalblock IMPORTANT DONOTswitchontheelectricitysupply untiltheshowercoverhasbeenfitted Thediagrambelowshowsaschematicwiring...

Page 14: ...liderswitchinupper position DIPswitchisOFFwhensliderswitchisin lowerposition SoundON sliderswitch4ON SoundOFF sliderswitch4OFF RunningTime30MINS sliderswitch1OFF sliderswitch2OFF sliderswitch3OFF Runn...

Page 15: ...elock tagsarealignedwiththeslotsonthedisplayPCB connector totherearofthefrontcoverasillustrated makingsurethattheconnectorpinsarefullyengaged Thecovercannowbefitted Pleaseensurethatthe flowcontrolknob...

Page 16: ...to therailbyturningthelockingcap Thenfitthe soapdish dampeningtherailwillmakeiteasier toslideon Finallyfitthehoseretainingringonto thebottomoftherailbelowthesoapdish 6 Replacetherailassemblythroughthe...

Page 17: ...appensonthefirststartupoperation IMPORTANT Ifthebuttondoesnotrespondensure thattheflyingleadfromthePCBhasbeenconnected tothebackofthefrontcover Ensurefrontcoveris isolatedatthemainssupplybeforeremovin...

Page 18: ...orwallmountedswitch IMPORTANT Whentheshowerisre starteditwill reachthetemperaturesetbythelastuserasthishas beenstoredintheunit smemory 3 Finallywerecommendthattheshowerheadis removedtomakesurenodebris...

Page 19: ...fortheshowertoincreasethetemperaturetothe newsetting 2 Repeatthisifnecessarytoachieveyourideal temperaturesettingwaitingeachtimeforthe newtemperaturetobeachieved IMPORTANT Forsafetythemaximumoutlet te...

Page 20: ...heshower isoperating 10 Astabiliserbuiltintothewaterflowvalve automaticallycompensatesforsmallfluctuations inwaterpressurethatfrequentlyoccurin households Therearethreefurthercontrolsthat caterforexce...

Page 21: ...urthumb overthesurfacewhilsttheshower isrunning 2 Ifscaledepositsarestubborn soak theshowerheadinaproprietary limescaleremoverandrinse thoroughlybeforeuse 3 Removethefilterfromthebottom oftheshowercle...

Page 22: ...tart stopbuttonandthiswillstopthewater flow Q WatertooHOT A Sixpossiblereasons 1 Selectacoolertemperaturebypressingthe cooler button 2 Selectahigherflowbyadjustingtherotaryflow knob 3 Cleantheshowerha...

Page 23: ...Waterisdrippingfromthebottomoftheshower A Safetypressurereliefmayhaveoperated This willneedtobereplaced PleasecontacttheMX serviceline Checktheinletmainswaterconnection Ifthepressurereliefvalvehasope...

Page 24: ...ingalowvoltage resistancemeterwhilstthepowerisswitchedOFF attheisolatingswitch Checkworkingvoltage Q Poorornocontroloverwaterflow A Replacethewaterflowvalveheadworks Q Nowaterwhenstart stopbuttonispre...

Page 25: ...ble 3 Originalproofofpurchase s mustbeshownforanyclaimunderthis guarantee 4 Thisguaranteedoesnotcoveranycomponentsthathavebeen modified alteredortransformedinanyway 5 Thisguaranteeappliestoanoriginali...

Page 26: ...e abletoinformyouwhetherthefaultcanberectified bytheprovisionofareplacementpartoranonsite visitbyaQualifiedServiceEngineer 3 Ifaservicecallisbooked youorarepresentative mustbepresentduringtheEngineers...

Page 27: ...27 Notes...

Page 28: ...CUSTOMERCARE 08455052211 TRADE DESCRIPTIONS ACT Variations in terms of colour finish materials and all other aspects of appearance may occur on occasions either through non availability of materials o...

Reviews: