Patriot - Testing & Adjusting Manual
Rev. 01/2016
Page | 33
Chargeable Accumulators:
Many applications will not require charging the accumulators; in those applications the
accumulator can be used as a surge chamber. These are low pressure spray or pour
applications where fluid pressures are medium to low.
In some cases only a line pressure charge on the resin accumulator will be necessary.
These will be applications where a medium fluid pressure is being used, most likely a
spray or a medium viscosity pour application. The line charge procedure uses the
charging hose attached to the air manifold.
For high fluid pressure applications charging the accumulators to 280psi to 300psi may
be required. These are applications using filled resins or spray putties. This will require
a charging pump or similar device a high pressure tank and regulators can also be
used.
If you do a test and find it necessary to charge the resin accumulator or both
accumulators repeat the test after performing the charging procedure to confirm an
even cure.
Charging Procedures: Line Charge
1.
Shut off air to the resin pump by either turning regulator to zero or turning the
pump control valve to the off position.
2.
Lock the gun in the on position over an appropriate container, or open the ball
valve at the bottom of the resin filter if one is installed.
Note: For catalyst charging lock the gun in the open position over an appropriate
container, or open the recirculation/dump valve on the manifold.
3.
Relieve any existing charge by inserting a blunt object (allen wrench) into the top
of the charging valve.
4.
Push the quick coupling on charging hose onto the charging valve on top of the
resin accumulator. Hold the in place for approximately 5 seconds.
Note: During charging of the accumulator, if air is heard exiting the front of the
gun or appropriate valve, this indicates that the polyball in the accumulator is not
seating properly. Repair the accumulator as needed.
5.
Remove the charging hose from the resin accumulator. Check the top of the
accumulator for air leaks by applying a light fluid (water) to the top of the
accumulator valve body. If air leaks remove and repair charging valve.