Patriot - Testing & Adjusting Manual
Rev. 01/2016
Page | 30
Pour Testing:
The same process and results that are used for testing the spray can be used for testing
a pour system. By pouring a bead of material in an up and down
”zig zag” pattern then
observing the results.
Result 8:
Material delivered on the catalyst pump down-stroke (from the top of the stroke to the
bottom) is not curing or slow cure (see figure above).
Indicates:
No catalyst is being delivered on the down-stroke.
Probable Cause:
Worn or damaged inlet body.
Worn or damaged inlet body ball.
Worn or damaged inlet body O-ring.
Solution:
Replace
worn and damaged parts, see
Service and Repair Manual.
Start Pour Test
Direction of gun travel
End Pour Test
B
B
B
T
T
Start Pour Test
Direction of gun travel
End Pour Test
B
B
B
B
T
T
T