Patriot - Testing & Adjusting Manual
Rev. 01/2016
Page | 27
Down stroke Upstroke
Down stroke Upstroke
Down stroke
T
B
T
B
T
B
Result 4:
Material delivered on the catalyst pump down-stroke (from the top of the stroke to the
bottom) is not curing or slow cure (see figure above).
Indicates:
No catalyst is being delivered on the down-stroke.
Probable Cause:
Worn or damaged inlet body.
Worn or damaged inlet body ball.
Worn or damaged inlet body O-ring.
Solution:
Replace
worn and damaged parts, see
Service and Repair Manual.
Start Spray Test
Direction of gun travel
End Spray Test
Result 5:
Material is delivered with streaks running the length of the test spray. Some strips cure
normally, some not at all, other cure at faster or slower rates (see figure above). This is
not a pumping problem, it is a mixing problem.
Indicates:
a mixing problem and the fan is delivering streams of poorly catalyzed
resin and/or pure catalyst.
Probable Cause:
the Static or Turbulent Mixer is worn, clogged or damaged in
some way. A scratched or damaged Mix Chamber can also cause this problem.
Solution:
shut down the system and inspect the Mixer and Mix Chamber.
Repair or replace as needed.
Normal cure
Slow / No Cure