© MuxLab Inc.
ProDigital Network Controller (MNC)
Page 220
Command:
{"p_targetId":0,"p_cmd":"changeAdminPswd","p_userName
":"<MNC User
Name
>","p_password":"
<MNC password>
","p_data":[{"usrname":"<the
user name>"}, {"currpswd":"<current passsword>"},{"newpswd":"<new
password>"}]}
Response:
{"p_targetId":0,"p_cmd":"
modifyNetSettings
","p_rspStatus":"
SUCSESS/
FAILED
","p_msg":"
<a message>
"
}
5.2.15 VIDEO WALL: Connection command (For 500754/759)
Description:
Set RX as video wall and connect it to a source (TX)
Command:
{"p_targetId":
<systemID>
,"p_cmd":"vwconnection","p_userName
":"<MNC User
Name
>","p_password":"
<MNC password>
","p_data":[{"macRx":"
<Rx device mac
address>
","macTx":"
<Tx device mac address to connect to>
","isVideoWallMode":true,
"vwGlobalSize":"
<Global nb of TV on x axis>
x
<global nb of TV on y
axis>
","vwSizeX":
<nb of TV of current video wall on x axis>
,"vwSizeY":
<nb
of TV of current video wall on y axis>
,"xCoordonate":
<x coordinate of
this RX>
,"yCoordonate":":
<x coordinate of this RX>
,"measureUnit":"
<
inch
or
cm
>
","screenWidth
":<
screen width
>
,"screenHeight":
<
screen
Heigth
>
,"bezelTop":
<measure of top Tv bezel>
,"bezelBottom":
<measure of
bottom Tv bezel>
,"bezelLeft":
<measure of left Tv
bezel>
,"bezelRight":
<measure of right Tv bezel>
,"scaleUpH":
<0 to
255>
,"scaleDownH":
<0 to 255>
,"scaleUpV":
<0 to 255>
,"scaleDownV":
<0 to
255>
,"shiftRight":
<0 to 255>
,"shiftLeft":
<0 to 255>
,"shiftUp":
<0 to
255>
,"shiftDown":
<0 to 255>
}, …]}
NOTE:
You have the option to use a port ID (to be defined in web server) instead of the mac
address
o
"portIn":"<input port number >"
o