© MuxLab Inc.
Extender Model 500755-AMP
Page 189
The 500755-AMP supports a bi-directional IR port. The below example is for
transmitting IR from the sink side (display/speaker side) to the source side, but the
500755-AMP can be configured to transmit IR from the source to the sink side as
well.
Once a device is selected, the
Data to send in HEX
field becomes enabled. In the
above example, source “Audio 1” was chosen as the selected device, meaning that a
command sent to source “Audio 1” will travel from the Network Controller to the
Ethernet Switch, then from the Ethernet Switch to the transmitter connected to source
“Audio 1”. The transmitter will then send the specified IR data command to source
“Audio 1” via the IR Emitter connected to the transmitter IR out port.
The
IR code received in HEX
field displays the HEX version of an IR command send
from a handheld remote to an IR receiver IR In port and attached IR Sensor.
When sending IR commands directly from an IR Source device, such as an IR
handheld remote, from 500755-AMP receiver through to a transmitter, the user must
set up a pass-through for IR signals to be sent to and from devices. This requires the
following step:
The user must tell the 500755-AMP receiver (being the device near the
IR handheld remote with an attached IR Sensor) the IP address of the
500755-AMP transmitter (where the IR commands are being sent,
which has an attached IR Emitter). This is done by first clicking on the
Select a device
drop-down list and selecting the local device from the
list, and then inputting the IP address of the far device in the
IP
Feedback
field. The user then clicks on
Save
.