Module Serial Configuration Parameter OIDs:
1.3.6.1.4.1.32345.88 + OID End
OID End
Name
R/W
Size, bytes
Range
Default
.3.1.0
SerialDivisor
R/W
4
0..2
32
-1
0x00000030 (9600 bps)
.3.2.0
SerialCharFormat
R/W
4
0..3
0x00000003 (8-bit)
.3.3.0
SerialStopBits
R/W
4
0..1
0x00000000 (1 stop bit)
.3.4.0
SerialParity
R/W
4
0..3
0x00000004 (no parity)
.3.5.0
SerialRxTimeout
R/W
4
0..2
32
-1
0x00000020 (32 ms)
.3.6.0
SerialFlowControl
R/W
4
0..1
0x00000000 (flow control disabled)
.3.7.0
DiagDivisior
R/W
4
0..2
32
-1
0x00000030 (9600 bps)
.3.8.0
DiagEnable
R/W
4
0..1
0x00000001 (diagnostic port enabled)
.3.9.0
SPI_Mode
R/W
4
0..2
0x00000000 (disabled)
.3.10.0
SPI_MasterClock-
Divisor
R/W
4
0..2
32
-1
0x00000001
.3.11.0
SPI_MasterCmd-
String
R/W
4
ASCII String
“” (null string)
Table 7.2.10
SerialDivisor
- this parameter sets the main serial port baud rate, equal to 460800 divided by
the SerialDivisor value.
SerialCharFormat
- this parameter sets the format for the main serial port as follows:
0x00000000 for 5-bit format
0x00000001 for 6-bit format
0x00000002 for 7-bit format
0x00000003 for 8-bit format (default)
SerialStopBits
- this parameter sets the number of stop bits for the main serial port as follows:
0x00000000 for 1 stop bit (default)
0x00000001 for 2 stop bits
SerialParity
- this parameter sets the parity configuration for the main serial port as follows:
0x00000000 for odd parity
0x00000001 for even parity
0x00000002 for mark parity
0x00000003 for space parity
0x00000004 for no parity (default)
SerialRxTimeout
- this parameter sets the received message timeout for the main serial port. A received
message is interpreted as complete when no additional bytes are received during a timeout interval. The
SerialRxTimeout parameter is scaled in milliseconds.
SerialFlowControl
- this parameter enables/disables /HOST_RTS - /HOST_CTS hardware flow control:
0x00000000 disables flow control (default)
0x00000001 for enables flow control
DiagDivisior
- this parameter sets this parameter sets the diagnostic serial port baud rate, equal to
460800 divided by the DiagDivisor value.
©2009-2015 by Murata Electronics N.A., Inc.
HN-210D/X, HN-214 D/X Rev. 2.0 01-16-15
Page 56 of 101