gsnTrapConfigIntTmr
- this parameter sets the interval for the module to transmit configuration traps. The
parameter scaling is in microcontroller clock cycles of 0.029802322 µs. This parameter is a 64-bit num-
ber, formatted as an ASCII string of the equivalent hexadecimal value.
gsnTrapLinkUpIntTmr
- this parameter sets the interval for the module to transmit linkup traps. The pa-
rameter scaling is in microcontroller clock cycles of 0.029802322 µs. This parameter is a 64-bit number,
formatted as an ASCII string of the equivalent hexadecimal value.
gsnSnmpTrapSrcPort
- this parameter holds the port number for the SNMP trap source. The parameter is
formatted as a 32-bit hexadecimal number.
gsnSnmpTrapDstPort
- this parameter holds the port number for the SNMP trap destination. The parame-
ter is formatted as a 32-bit hexadecimal number.
gsnSnmpPsPollTimer
- this parameter sets the interval that the module polls the access point to send any
data the access point is holding for it. Parameter scaling is in microcontroller clock cycles of 0.029802322
microseconds. This parameter is a 64-bit number formatted as an ASCII string of the equivalent hexadec-
imal value.
Trap Parameter (traps) OIDs:
1.3.6.1.4.1.28295.1.1 + OID End
OID End
Name
R/W
Size, bytes
Range
Default
.4.2.1
Linkup
N/A
N/A
N/A
N/A
.4.2.2
Config
N/A
N/A
N/A
N/A
.4.2.4
Time (sync update)
N/A
N/A
N/A
N/A
.4.2.6
Battery Low
N/A
N/A
N/A
N/A
Table 7.2.5
Linkup
- trap to maintain link association.
Config
- trap to request any pending configuration updates.
Time sync update
- trap to request time sync update.
Battery Low
- low battery warning trap.
Time Configuration Parameter (timesynccfg) OIDs:
1.3.6.1.4.1.28295.1.1 + OID End
OID End
Name
R/W
Size, bytes
Range
Default
.5.5.0
gsnTimeSyncTmr
R/W
8
ASCII String
“00000000” (disabled)
.5.6.0
gsnTimeSyncSntpSrvrIp
R/W
4
0..2
32
-1
0xC0A803C8 (192.168.3.200)
.5.7.0
gsnTimeSyncSntpSrvr-
TimeOut
R/W
4
0..2
32
-1
0x00000003 (3 seconds)
Table 7.2.6
gsnTimeSyncTmr
- this parameter sets the interval that the module polls the time sync server. Parameter
scaling is in microcontroller clock cycles of 0.029802322 µs. This parameter is a 64-bit number formatted
as an ASCII string of the equivalent hexadecimal value. This parameter defaults to zero, disabling the
©2009-2015 by Murata Electronics N.A., Inc.
HN-210D/X, HN-214 D/X Rev. 2.0 01-16-15
Page 52 of 101