3
2
Provide Weather
Shelter Over Fans
150mm
Min.
Fan with
Discharge Cone
Snow Guards located
per manufacturers
recommendations
Ceiling
Figure 28
Winterizing
7
.
Fan with
Discharge
Cone
Note:
Snow guards are designed to prevent sudden, dangerous snow
and ice slides when attached to the building roof according to
manufacturers recommendations. The supplier listing above is given
as a reference only.
Munters
does not endorse any specific snow
guard product and no performance warranty is implied.
Munters Product and System
Warranties do not cover cone or fan
damage from external sources.
IMPORTANT
!
Figure 27
In most climates, it is probable that the ventilation system will never need to operate at a total capacity
during the colder winter months. Consequently, it is advisable to “winterize” those fans which will not
be used in cold weather to avoid unnecessary heat loss and condensation.
To winterize, turn fan control “off”. Install the insulated closure panel over the fan intake. If you don’t
have an insulated closure panel, a piece of rigid insulation material can be used. Remember the
insulation panel must be removed before warmer weather returns.
NOTE:
At least one single speed fan should be left uncovered and with power available to provide air
movement in the event of variable speed control difficulties.
7.1 Winterizing
7.2 Winter Weather Protection
To prevent cone or fan damage from snow or ice sliding off building roof, weather protection must be
provided. A weather shelter may be constructed to cover the entire fan,
See Figure 27,
or snow guards
may be placed on the roof,
See Figure 28.