© Munters AB, 2020
102
6. In System > Control Strategy > Ventilation
, enable Extra Ventilation and/or Tunnel (refer to
Defining Extra Ventilation, page 122).
7. In Climate > Min. Max. Ventilation, click
.
8.Place the cursor in Min Level or Max Level. The Basic/Extra/Tunnel icons appear.
9. Click the required ventilation icon.
10. Define the ventilation as required.
12.2.1
D
EFINING
D
YNAMIC
V
ENTILATION
Dynamic Ventilation means that at extreme temperatures (which the user defines), ventilation can be
increased or decreased.
1. Go to System > Control Strategy > Ventilation
.
2. Under Minimum / Maximum Ventilation, enable:
o
Dynamic Minimum Ventilation or
o
Dynamic Maximum Ventilation or
o
Both. In this example both are enabled.
3. Go to Climate > Min/Max Ventilation > Settings.