4. Define:
o
Dynamic Minimum Cold/Warm Outside T⁰ To Target: Define the cold and warm
differentials from the target temperature at which dynamic ventilation begins operating.
o
Dynamic Maximum Cold/Warm Outside T⁰ To Target: Define the cold and warm
differentials from the target temperature at which dynamic ventilation begins operating.
5. Go to Climate > Min/Max Ventilation.
6. Define:
o
Cold Min.: When the outside temperature reaches the Dynamic Minimum Cold Outside
Temperature, Minimum Ventilation is reduced by this amount.
o
Warm Min: When the outside temperature reaches the Dynamic Minimum Warm
Outside Temperature, Minimum Ventilation is increased by this amount.
o
Cold Max. Level: When the outside temperature reaches the Dynamic Maximum Cold
Outside Temperature, Minimum Ventilation will not go above this level.
o
Warm Max. Level: When the outside temperature reaches the Dynamic Maximum
Warm Outside Temperature, Minimum Ventilation will not go above this level.
Summary of Contents for Rotem Trio 20
Page 20: ... Munters AB 2020 20 Figure 6 Relay and port numbering ...
Page 44: ... Munters AB 2020 44 ...
Page 99: ... Munters AB 2020 99 Refer to Tunnel Ventilation page 123 for more details ...
Page 141: ... Munters AB 2020 141 If an outside temperature sensor is enabled map timers to it if required ...
Page 160: ... Munters AB 2020 160 23 3 2TRIO 20 CONTAINER SPARE PARTS ...
Page 162: ... Munters AB 2020 162 23 3 3TRIO 20 DOOR CARDS SPARE PARTS ...
Page 164: ... Munters AB 2020 164 23 3 4TRIO 20 MAIN CONTAINER SPARE PARTS ...
Page 186: ... Munters AB 2020 186 Figure 33 Relay and port numbering 26 2 3POWER Figure 34 Power ports ...
Page 199: ... Munters AB 2020 199 2 Insert and secure the SMA connector ...
Page 202: ... Munters AB 2020 202 example only ...