![Munters Rotem Trio 20 User And Installation Manual Download Page 50](http://html.mh-extra.com/html/munters/rotem-trio-20/rotem-trio-20_user-and-installation-manual_1856897050.webp)
© Munters AB, 2020
50
3. Under Devices or Sensors, click the type of device that you want to map. In the following
example, Heater is selected. The displays the relays and ports that can be defined as heaters.
4. Click on the relays and/or ports that you wired to heaters.
o
Trio automatically numbers the devices.
o
Trio enables selecting up to the maximum number of each device.
o
Devices having opening and closing relays require mapping both relays.
5. Repeat steps 3 and 4 four all the connected devices.
6. After mapping all installed devices, click
.
NOTE
To un-map a device, click on the required device and hold the icon down.
Summary of Contents for Rotem Trio 20
Page 20: ... Munters AB 2020 20 Figure 6 Relay and port numbering ...
Page 44: ... Munters AB 2020 44 ...
Page 99: ... Munters AB 2020 99 Refer to Tunnel Ventilation page 123 for more details ...
Page 141: ... Munters AB 2020 141 If an outside temperature sensor is enabled map timers to it if required ...
Page 160: ... Munters AB 2020 160 23 3 2TRIO 20 CONTAINER SPARE PARTS ...
Page 162: ... Munters AB 2020 162 23 3 3TRIO 20 DOOR CARDS SPARE PARTS ...
Page 164: ... Munters AB 2020 164 23 3 4TRIO 20 MAIN CONTAINER SPARE PARTS ...
Page 186: ... Munters AB 2020 186 Figure 33 Relay and port numbering 26 2 3POWER Figure 34 Power ports ...
Page 199: ... Munters AB 2020 199 2 Insert and secure the SMA connector ...
Page 202: ... Munters AB 2020 202 example only ...