Heating Devices
Define up to six relays and/or analogue output ports as heaters in Mapping Devices, page
48.
•
•
7.5.1
D
EFINING THE
O
N
/O
FF
H
EATERS
•
Define:
o
Zone Heater:
Disable (default): Central Heaters, the heater output is related to the target
temperature, these heaters operate according to the average temperature (no
temperature sensors can be assigned to it).
Enable: Zone Heater, the heater output has its own target set-point and its own
sensors assign to it. Zone heater will enable the assignment of temperature
sensor/s in temperature definition.
o
Operation: Define the relay mode.
o
Operation Modes
Continues (default): The heater starts to operate continuously
Cycle: This option enables the operation of heater in cycles.