© Munters AB, 2015
92
8.6
Static Pressure
Observe the converter readings for the static pressure sensor. The nominal ‘zero’ pressure reading is
130. Remove the air hoses from the brass connectors on the left side outside of the controller to check
this reading.
8.7
Communication
This menu facilitates testing on communication networks. A multiplexer in loop back mode is used to test
the communication. The Farm Premium follows its' own communication to check for failed hardware.
Follow the instructions displayed on the screen
.
ANAGLO OUT TEST
Output. Sensor
0 – 10v
1
Light Dimmer 1
0.0
2
Light Dimmer 2
0.0
3
Light Dimmer 3
0.0
4
Var. Heat
0.0
5
W.O.D
0.0
6
<None>
0.0
7
<None>
0.0
8
<None>
0.0
STATIC PRESSURE
A/D Counts
126
To perform this test you
must short RX with TX on
the non-priority channel of
the multiplexer
PRESS ENTER TO CONFIRM