![Munters Farm P-XL User Manual Download Page 124](http://html.mh-extra.com/html/munters/farm-p-xl/farm-p-xl_user-manual_1856887124.webp)
© Munters AB, 2015
124
opens to 100%, calibrates, and returns to the previous position. If the curtain is open less than
50% it closes to 0%, calibrates, and returns to the previous position. Default: 99.
Figure 23: Example of Inlet Opening Hysteresis
Figure 25 illustrates an example of inlet hysteresis. An inlet is set to open to 50%, with a compensation of
3% for each degree. The target temperature is 80.0
°
, with a hysteresis of 0.5
°
. Between 79.5
°
to 80.5
°
,
the inlet remains at 50%. If the temperature rises to 81.0
°
, the opening goes to 53%.
12.3
Layer Dimmers
Layer mode supports up to ten analog dimmer channels.
ANALOG OUTPUT
Out
Num Function
Num
Min
V.Out
Max
V. Out
1
Light Dimmer
1
0.0
10.0
2
Light Dimmer
2
0.0
10.0
3
Light Dimmer
3
0.0
10.0
4
Light Dimmer
4
1.0
9.0
5
Light Dimmer
5
1.0
9.0
6
Light Dimmer
6
1.0
9.0
7
Light Dimmer
7
1.0
9.0
8
Light Dimmer
8
0.0
10.0
9
Light Dimmer
9
0.0
10.0
10
Light Dimmer
10
0.0
10.0