© Munters AB, 2015
79
6.3
Bird Scale Setting
NOTE:
Only Broiler/Layers Mode supports this function.
There are two different weighing options available; select the option in
Scale > General Settings
.
•
Start Time: Set the hour you would like
the scale to begin weighing
•
Start Time: Set the hour you would
like the scale to begin weighing
•
End Time: Set the hour you would like the
scale to stop weighing
•
End Time: Set the hour you would
like the scale to stop weighing
•
Range – (0-100%): Band above and
below reference weight
•
Range – (0-100%): Band above
and below reference weight
•
Reference Weight 1: Starting out weight
for scale 1
•
Reference Weight 2: Starting out weight
for scale 2
6.4
Silo Setting
These settings help you monitor your silo through weighing. There are two events that take place,
emptying (feeding) and filling (loading).
NOTE:
Silos must be defined in
Scale Layout
for the following parameters to be functional.
•
Minimum Emptying Weight (Default: 20 Kg): Define the accumulated emptying weight from
the bin during feeding time for it to be recorded as an event. Once it has been recorded, the
counter resets.
•
Minimum Filling Weight (Default: 2000 Kg): Define weight required to be filled during
loading to be recorded in History –
; History –
; Scale –
•
Filling Detection Weight (Default: 300 Kg): Define the weight you want your controller to
detect a filling to stop augers.
•
Resume Time (minute) (Default: 5 min.): Once loading is completed, define the time you want
your controller to count down for the augurs to resume normal operation.
BIRD SCALE SETTING - SEXED
Start Time
End Time
Range – (0 – 100%)
Reference Weight 1
Reference Weight 2
18:00
19:00
30
0.13
0.11
BIRD SCALE SETTING - MIXED
Start Time
End Time
Range – (0 – 100%)
18:00
19:00
20
SILO SETTING
Minimum Empty Weight
Minimum Filling Weight
Filling Detection Weight
Resume Time (minute)
20
2000
300
5