The Farm Premium has six options besides controller failure or power off to activate the fail-safe relay.
Apply the additional settings by using the '+/-' key:
•
High/Low Temperature: Select to trigger fail-safe when the temperature is exceptionally
high/low.
•
Low/High Static Pressure: Select to trigger fail-safe when the static pressure is exceptionally
low/high.
•
Avg. Temperature Fail: Select to trigger fail-safe when all sensors in house fail.
•
AUX: Select to trigger fail-safe when auxiliary dry contact occurs.
5.8
Password
The owner can set new passwords for himself, all users and visitor. The owner cannot see user passwords
once entered or changed by the users. The users can access the controller and make changes to all
controller settings and their own password. A user can only see and change the user's own password.
The visitor can access the controller, but cannot make changes. Each time someone accesses the
controller with a password, an event is recorded in the
NOTE:
If your controller uses passwords, the controller also requires a password entry to
acknowledge switch position changes. If the switch change is not acknowledged the controller
signals an alarm.
5.9
Relay Current
NOTE:
The Relay Current feature supports
single phase electricity
only.
This menu configures the relay current sense parameters. You can configure:
•
the minimum and maximum amperage flowing to the relays
•
the relay current alarm
•
voltage type
NOTE:
Configuring the amperage is not required. The Farm Premium controller automatically
configures default settings.
PASSWORD
Owner Password
User-1 Password
User-2 Password
User-3 Password
User-4 Password
User-5 Password
Visitor Password
_ _ _ _
_ _ _ _
_ _ _ _
_ _ _ _
_ _ _ _
_ _ _ _
RELAY CURRENT SETTING
Rly. Function Min Nom Max Alr Vlt
31 Heat 6
2.7 3.8 5.0 NO 110
32 Heat 7
2.7 3.8 5.0 NO 110
33 Heat 8
3.0 3.8 5.6 NO 110
34 Exh. Fan 5 2.7 4.3 5.0 NO 110
35 Exh. Fan 6 2.3 3.8 5.0 NO 110
36 Tun. Fan 1 3.0 4.3 5.6 NO 110
37 Tun. Fan 2 0.0 0.0 0.0 NO 110
38 Tun. Fan 3 0.0 0.0 0.0 NO 110