© Munters AB, 2015
128
5. To adjust the target temperature during feeding (to increase ventilation):
a. Define the To/From times.
b. Define the Target Temperature Offset (to reduce the target).
NOTE:
To disable this feature set the offset to 0.
6. To control the male breeders feeding time:
a. Under Feed Line Operation, define when the lines descend and rise (Line Down, Line Up
times).
b. Go to
Service > Feed Line Calibration
.
c. Enter the amount of time required for the curtains to rise and descend.
NOTE:
Measure these times if you don't know them.
Additional points:
•
In Breeder Mode, Farm Premium supports up to:
•
10 feeders
•
Four water lines
•
Four augers
•
Define these functions in
Install > Relays
.
•
To and From times can overlap. For example, in the table above one line goes from 4:45 to 5:15 and
the next line goes from 5:00 to 5:30. If there is overlap and contradictory configurations, the priority is
Continuous > Cycle > Off. In the example above:
•
Water Line 2 will run in a cycle from 5:00 until 5:30.
•
Feeder Line 1 will be on 4:45 until 5:15, even though the line 3 turns off the feeder.
13.3
Egg Belt Runtime
Farm Premium Breeder supports measuring the egg belt runtime.
Install digital input cards.
1. Go to
Install > Digital Sensors
.
2. Define a sensor as Egg Belt.
FEED LINE CALIBRATION
Function
Run Time (sec).
Feed Line 1 Up
60
Feed Line 1 Down
50
Feed Line 2 Up
80
Feed Line 2 Down
40
DIGITAL SENSORS
In
Function
Num
1
Water Meter
1
2
Auger – 1 Overtime
1
3
Cool Pad Water Meter
1
4
Fogger Water Meter
1
5
Water Meter
2
6
Feeder Over Time
1
7
Egg Belt
1
8
< None >
0