Part Number: 9290312 May/17/2016 23
Section 4
Maintenance
20. Towards the end of sanitizing process there will be
a system purge process and once bubbles are seen
coming from five (5) gallon bucket, close plain coffee tap.
21. Once sanitizing process is complete cleaning button
will not be illuminated, which indicates sanitizing is
complete and both product taps should be closed.
22. Disconnect sanitizer solution keg and set aside.
23. Mix proper concentration of approved sanitizing solution (400
ppm Quat concentrate) in the second three (3) gallon keg.
24. Connect the inlet and outlet keg connectors of unit to
the sanitizer solution keg.
25. Press and release the Prime/Clean button to prime the
system with cleaning solution. The LED around the
button will flash ON then OFF.
26. Empty the five (5) gallon bucket and place ends of clear
nozzle drain hoses back into bucket.
27. Repeat Step 9 and 10, again unit will automatically run
through sanitizing process.
28. Towards the end of rinse process there will be a system
purge process and once bubbles are seen coming from
five (5) gallon cleaning bucket, close plain coffee tap.
29. Once rinsing process is complete the LED will not be
illuminated, which indicates rinsing is complete and
both product taps should be closed.
30. Disconnect warm rinse water keg and set aside.
31. Disconnect clear drain hoses from tap nozzles, empty
five (5) gallon catch bucket and store for use during
next weekly cleaning.
32. Complete all weekly cleaning task before reconnecting
coffee keg to unit.
Imprtant
Kegs used for cleaning, sanitizing solutions and rinse
water should be emptied and cleaned before reuse.
Keg Cpnnectpr Cleaning
1. If keg is not disconnected, then do so and set keg aside.
n
Warning
NEVER ATTEMPT TO REMOVE KEG LID WITHOUT FIRST
DE-PRESSURIZING KEG!
2. Spray cleaner on one keg connector and wipe down
with clean towel.
3. If required a brush can be used for stains or residue
build-up.
4. Repeat Step 1 and 2 for other keg connectors.
Keg Cpnnectpr Cleaning & Sanitizing
• Frequency: every week or as required.
1. Mix proper concentration of approved sanitizing
solution (400 ppm Quat concentration) in clean bucket
and place keg connectors into bucket and allow to soak
for 15 minutes , or as directed by manufacturer.
NOTE: An alternative method is to heavily spray both
of the connectors with sanitizing solution and allow
sanitizer to remain for fifteen (15) minutes or as directed by
manufacturer.
2. Once keg connectors are cleaned and sanitized each
one should be immersed into clean water for at least
five (5) minutes for rinsing.