19
Section 3
6. The heat dump must be connected using a minimum of 1.5mm2 two core cable. If
a smaller cable is used , a voltage drop will occur which will cause the fan to run at a
lower speed.
7. If the unit is to be installed in a building or room, ensure there is adequate
YHQWLODWLRQZLWKLQWKHURRPWRHQDEOHWKHKHDWWREHGLVVLSDWHGHHFWLYHO\
Temperatures within the room should not exceed 40°C.
'RQRWNLQNWKHȵRZDQGUHWXUQWXEHVZKLFKZRXOGUHVWULFWWKHFRRODQWȵRZ
'RQRWLQVXODWHWKHȵRZDQGUHWXUQOLQHV
7KHȵRZDQGUHWXUQOLQHVPXVWQRWEHVWUDSSHGWRJHWKHUDVKHDWWUDQVIHUEHWZHHQ
WKHWZRZLOODHFWWKHV\VWHPSHUIRUPDQFH
11. Ensure that the heat exchanger matrix of the heat dump is kept clean and free
from obstruction. It is recommended that it should be cleaned with a soft brush at
regular intervals.
Please refer to the Heat Dump manual (Part No PI015362) for additional information.
GLYCOL MODULE INSTALLATION (WATER COOLED UNITS ONLY) -
GENERAL GUIDELINES
1. Site the glycol pump module within 2 meters of the base unit and use the bracket
supplied to secure the module to a wall.
2. Connect the glycol modules power supply to the 230V power socket on the base
unit. (DO NOT SWITCH ON YET)
3. Using the correct glycol tubing (15mm O\D, 10mm I\D special EVA) connect the
COOLANT FLOW from the glycol module to COOLANT RETURN on the base unit.
4. Again using the correct tubing, connect the COOLANT FLOW from the base unit
to the FLOW on the heat dump. Connect the RETURN on the heat dump to the
COOLANT RETURN on the base module to complete the circuit.
5. Connect the 1.5mm2 twin wire from the heat dump to the 24V outlet socket on the
glycol module using the two pin plug supplied or to the screw terminal connectors
(or spring loaded connectors on the glycol module. (Dependent on model) it does
not matter which way the wires are connected as they are not polarised.