11
Section 3
AMBIENT CARBONATED UNITS – CONNECTING THE UNIT TO THE WATER, CO2,
PYTHON AND COMMISSIONING.
1. If the unit is a water cooled version, the glycol module and heat dump must be
installed and connected as detailed in the Glycol module and heat dump installation
guidelines before commissioning the complete system.
2. Install the Ambi Carb unit as per the Ambient Carbonator instruction manual. Then
connect the carbonated water feed from ambient carbonator to the tube at the
front of the unit labelled CARB WATER IN. It is recommended that the maximum/
minimum CARBONATED WATER pressure to the unit is 80/75 psi.
5HPRYHWKHȴOOHUFDSIURPWKHOLGDQGUHGHQGVWRSIURPRYHUȵRZWXEH8VLQJD
IXQQHOȴOOWKHZDWHUEDWKZLWKIUHVKFOHDQFROGZDWHUSUHIHUDEO\EHORZr&XQWLO
ZDWHUMXVWWULFNOHVIURPWKHRYHUȵRZDSSUR[OLWUHV)LWWKHUHGHQGVWRSWRWKH
RYHUȵRZSXVKLQJKRPHWRDFKLHYHDVHDO$OWHUQDWLYHO\SOXPEWKHRYHUȵRZWRD
SHUPDQHQWGUDLQ5HSODFHWKHȴOOHUFDSLQWKHOLG$Q\H[FHVVZDWHUZLOOQRZEH
URXWHGWRDQLQWHUQDORYHUȵRZDQGZLOOEHHYDSRUDWHGRE\WKHUHIULJHUDWLRQV\VWHP
YLDWKHLQWHUQDOERLORWUD\
4. If required, dose the water with the provided biocide control agent in accordance
with the instructions supplied on the bottle, taking note of health and safety
instructions.
5. Connect the syrup inlet lines to the syrup coils labelled SYRUPS IN 1-5.
&RQQHFWWKH6RGDUHFLUFȵRZDQGUHWXUQOLQHVZLWKLQWKHS\WKRQWRWKHFRQQHFWLRQV
labelled SODA IN and SODA OUT ensuring these connections are insulated with
VXLWDEOHDUPDȵH[
1
2
5
4
3
4
3
5
1
2
SYRUPS IN
SYRUPS OUT
CARBONATOR WATER
IN
STILL IN
SODA IN
STILL OUT
SODA OUT
CONNECTION NOTES
SYRUP COILS 1-5: 5/16” PLAIN RINGED ENDS
SODA STILL & CARBONATOR WATER LINES 3/8” PLAIN RINGED ENDS
01-3001-01 WATER COOLED NOTE:
HEAT DUMP FLOW AND RETURN FITTINGS 15MM (SUPPLIED WITH UNIT)