22
Section 3
1. To adjust the Cut-Out Temperature:
A. Carefully remove the lens from the front of the controller.
B. Press and hold the button. Release after 2 seconds.
C. The display will change from ‘Current Temperature’ to ‘Current Set-Point’.
D. Adjust the temperature up or down using the (+) or (-) button.
E. To store the new set-point, press the button.
) 7KHGLVSOD\ZLOOWKHQVKRZWKHGLHUHQWLDOWHPSHUDWXUHȇΖIQRGLHUHQWLDO
adjustment is necessary, replace the lens. The unit will revert to the ‘Current
Temperature’ after 30 seconds.
7RDGMXVWWKH'LHUHQWLDO&XWΖQ7HPSHUDWXUH
A. Follow steps (a) and (b) above.
B. The display will change from ‘Current Temperature’ to ‘Current Set-Point’.
C. Press and hold the button again. Release after 2 seconds.
'7KHGLVSOD\ZLOOFKDQJHIURPȆ&XUUHQW6HW3RLQWȇWRȆ&XUUHQW'LHUHQWLDOȇ
E. Adjust the temperature up or down using the (+) or (-) button.
F. To store the new set-point, press the button.
([DPSOHΖIWKH&XW2XW7HPSHUDWXUHLVVHWDWr&WKH'LHUHQWLDO7HPSHUDWXUHPXVW
be set to 2.5°C to cause the unit to cut-in at 0.5°C.
3. To adjust the opening and closing hours:
Note: This feature allows up to 2 opening and closing sessions per day. The Manitowoc
GHIDXOWVHWWLQJDVVXPHVDVLQJOHKRXURSHUDWLQJSURȴOHSHUGD\ZLWKDKRXU
shutdown period at night. However, instructions are included on how to set-up a
second dispense period per day, if required.
Opening and closing hours set-up, beginning Sunday:
A. Carefully remove the lens from the front of the controller.
B. Press and hold the button. Release after 2 seconds.
C. The display will change from Current Temperature to Current Set-point.
D. Continue to scroll through the menu, by pressing the button for 2 seconds, then
releasing, until the display shows “HOUR”.
E. Press and release the button to enter the Opening/Closing hours mode.
) 7KHGLVSOD\EHJLQVZLWK6XQGD\GLVSOD\HGDVVXQ1RWHWKHȴUVWOHWWHUVRI
each day is displayed digitally by LEDs, and is not particularly easy to decipher
for some of the days.
G. To adjust the trading hours for Sunday, in 10 minute increments, follow this
procedure....