Section 4
In the event of Freezing Up occurring, the following action is recommended:
1. Isolate the unit from Mains Electricity Supply.
2. Identify the fault and rectify.
3. Isolate Product Supply from unit and depressurise the system.
4. Apply gentle warmth to the general area of the unit and its Pipe work.
5. Check for obvious leaks.
6. Turn product supply on / re-pressurise the system whilst continually
watching for leaks.
7. Reconnect Mains Electricity supply
Observe the unit running for a short period watching out for Leaks, strange noises or
any other form of malfunction, if no problems are observed then normal operation of
the unit may be resumed.
DISMANTLING / DECOMISSIONING PROCEDURE
1. Isolate the unit and or the ambient carbonator from the mains electrical supply.
(Depending on if it is an ambient carbonated unit or a cold carbonated unit)
7XUQRWKHZDWHUVXSSO\WRWKHDPELHQWFDUERQDWRUOHDYLQJWKH&2SUHVVXUHRQ
3. Ensure the area is well ventilated before purging the system
4. Drain the system down using the CO2 pressure to empty the carbonator
bowl, soda recirculation lines and syrup lines.
Note:
8VLQJDEDJLQER[DGDSWRULWLVUHFRPPHQGHGWKDWWKHV\UXSOLQHVVKRXOGEHȵXVKHGZLWK
water prior to draining to remove all traces of syrup.
7XUQRWKH&2VXSSO\DWWKHERWWOHDQGGHSUHVVXULVHWKHV\VWHPLQFOXGLQJ
syrup pump CO2 supply) by opening the dispense valves and by lifting the relief
valve on the ambient carbonator.
6. Disconnect the unit from the mains water supply, python product lines and the
ambient carbonator if applicable.
7. Siphon or pump out the water from the bath.
IMPORTANT:
FAILURE TO REMOVE ALL COOLANT FROM THE UNIT COULD RESULT
IN SUBSTANTIAL AMOUNTS OF COOLANT BEING RELEASED, WHICH MAY BE
DETRIMENTAL TO THE UNIT AND/OR ITS SURROUNDINGS. EXCESS COOLANT WILL
ALSO INCREASE THE MAXIMUM WEIGHT OF THE UNIT IF IT IS NOT REMOVED.